The construction and electrodes characteristics of poly(vinylchloride) (PVC)-based polymeric membrane electrode (PME) and coated graphite electrode (CGE), incorporating 1,3-alternate thiacalix[4]crown as ionophore for estimation of Hg(II) ions, are reported here. The best potential response was observed for PME-1 having membrane composition of: ionophore (6.2 mg), PVC (100.0 mg), 2-nitrophenyl octyl ether (2-NPOE; 200.0 mg), and sodium tetraphenyl borate (NaTPB; 2.0 mg); for CGE-1- with the membrane composition: ionophore (3.5 mg), PVC (40.0 mg), 2-NPOE (80.0 mg), and NaTPB (2.0 mg). The electrodes exhibits Nernstian slope of 29.16 mV/decade with PME-1 and 30.39 mV/decade with CGE-1 for Hg(II) ions over wide concentration range, i.e., 1.0×10~(-1) to 5.0 × 10~(-6)M with PME-1 and 1.0× 10~(-1) to 5.0×l0~(-7)M with CGE-1. Lower detection limits were found to be 9.77× 10~(-6)M for PME-1 and 7.76×10~(-7)M for CGE-1 with response time varying from 10 to 20 s. Also, these electrodes work within pH range of 2.0-6.0 for PME-1 and 1.5-6.5 for CGE-1. Overall, CGE-1 has been found to be better than PME-1. CGE-1 has been used as indicator electrode for the potentiometric titration of Hg(II) ions with EDTA as well as successfully applied for determination of Hg(II) content in wastewater, insecticide, dental amalgam, and ayurvedic medicines samples with very good performance (0.9974 correlation coefficient in the comparison against volumetric method).
机译:聚氯乙烯(PVC)基聚合物膜电极(PME)和涂层石墨电极(CGE)的结构和电极特性,结合了1,3-交替的噻唑杯[4]冠作为离子载体,用于估算Hg(II)离子,在这里报告。对于膜组成为:离子载体(6.2 mg),PVC(100.0 mg),2-硝基苯基辛基醚(2-NPOE; 200.0 mg)和四苯基硼酸钠(NaTPB; 2.0 mg)的PME-1,观察到最佳的电位响应);对于具有膜组成的CGE-1-,离子载体(3.5 mg),PVC(40.0 mg),2-NPOE(80.0 mg)和NaTPB(2.0 mg)。对于Hg(II)离子,在较宽的浓度范围内(1.0×10〜(-1)至5.0×10〜(使用PME-1的-6)M和使用CGE-1的1.0×10〜(-1)至5.0×10〜(-7)M。发现下限为PME-1为9.77×10〜(-6)M,CGE-1为7.76×10〜(-7)M,响应时间为10到20 s。而且,这些电极在PME-1的pH范围为2.0-6.0和CGE-1的pH范围为1.5-6.5的范围内起作用。总体而言,已发现CGE-1优于PME-1。 CGE-1已用作EDTA电位滴定Hg(II)离子的指示电极,并已成功用于测定废水,杀虫剂,牙科汞合金和阿育吠陀药物样品中Hg(II)的含量,性能非常好(与体积法比较时的相关系数为0.9974)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号