...
首页> 外文期刊>Equine Veterinary Journal >Dynamic respiratory endoscopy in 67 Thoroughbred racehorses training under normal ridden exercise conditions
【24h】

Dynamic respiratory endoscopy in 67 Thoroughbred racehorses training under normal ridden exercise conditions

机译:正常骑乘运动条件下67匹纯种赛马训练中的动态呼吸内窥镜检查

获取原文
获取原文并翻译 | 示例
           

摘要

Reasons for performing study: There are potential advantages to imaging the upper portion of the respiratory tract (URT) of horses during ridden exercise. With the advent of a wireless endoscope, this is now possible. However, there has been no detailed validation of the technique and findings have not been compared to ridden speed.Objectives: To assess the combined use of a Dynamic Respiratory Scope (DRS) and global positioning system (GPS) receiver for examining the URT of a group of Thoroughbred racehorses randomly selected from a single flat racehorse training establishment.Methods: Horses were selected randomly from a population of Thoroughbred horses in training at the same training yard. Endoscopic images of the URT were recorded during a ridden exercise test on an 'all-weather-gallop' and were reviewed post testing. Speed was measured using a wrist mounted GPS receiver.Results: A total of 67 (34%) of the 195 horses in training were examined. Endoscopic findings included: normal URT function (44 cases); dorsal displacement of the soft palate (DDSP) (13 cases); laryngeal asymmetry (4 cases); and axial deviation of the aryepigiottic folds (3 cases). Maximum speed obtained by individual horses ranged from 41.8-56.3 km/h. Ridden speed was variably affected by DDSP.Conclusions: The DRS provides a safe effective system for imaging the equine URT during ridden exercise at speed. The abnormalities of the URT identified were similar to those observed during treadmill endoscopy studies reported in the literature. The effect of URT abnormalities on ridden speed requires further investigation.Potential relevance: This technique can be used to diagnose common causes of URT associated with poor performance in horses during normal training. This has substantial implications for future clinical diagnosis and treatment of URT pathology.
机译:进行研究的原因:在骑马运动中对马的呼吸道(URT)上部进行成像可能具有优势。随着无线内窥镜的出现,这已经成为可能。然而,目前尚无对该技术的详细验证,也未将研究结果与骑行速度进行比较。目的:评估动态呼吸范围(DRS)和全球定位系统(GPS)接收器结合使用以检查机器人的URT的方法。方法:从同一训练场中接受训练的纯种马群体中随机选择马匹。在“全天候疾驰”骑行运动测试期间记录了URT的内窥镜图像,并在测试后进行了审查。使用腕上安装的GPS接收器测量速度。结果:在训练的195匹马中,总共检查了67匹(34%)。内镜检查结果包括:URT功能正常(44例);软pa背侧移位(DDSP)(13例);喉不对称(4例);鼻咽褶皱的轴向和轴向偏移(3例)。单匹马获得的最高速度为41.8-56.3 km / h。结论:DRS提供了一种安全有效的系统,可以对骑行速度快的马进行URT成像。所确定的URT异常与文献报道的跑步机内窥镜研究中观察到的异常相似。 URT异常对骑行速度的影响有待进一步研究。潜在相关性:该技术可用于诊断与正常训练期间马匹表现不佳相关的URT常见原因。这对URT病理学的未来临床诊断和治疗具有重大意义。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号