Failure investigation was carried out on corroded Muntz tubesheet and Ti tubes of a surface condenser. The Muntz metal was found to have suffered from corrosion grooves and micropits, which were crystallographic in nature. X-ray mapping revealed the occurrence of dezincification. The Ti tube ends suffered from separation and cracking of the deformed grains in addition to shallow localized attack. Corrosion of the Muntz metal was attributed to coupling with Ti, while corrosion of Ti was due to formation of Ti-hydride as a result of the utilization of sacrificial Al anodes in the waterbox. Seasonal variations in seawater temperature and proximity of Ti tube ends to waterbox anodes may have aided hydriding of the Ti tubes. Recommendations were given to discontinue the application of sacrificial cathodic protection and to epoxy coat the cast iron waterbox and the Muntz tubesheets.
机译:对表面冷凝器的腐蚀的Muntz管板和Ti管进行了故障研究。发现Muntz金属具有腐蚀槽和微坑,这些腐蚀槽和微坑本质上是晶体学的。 X射线图显示脱锌的发生。除浅的局部腐蚀外,钛管端部还受到变形晶粒的分离和破裂的影响。 Muntz金属的腐蚀归因于与Ti的结合,而Ti的腐蚀归因于水箱中牺牲Al阳极的利用,形成了氢化钛。海水温度的季节性变化以及Ti管末端与水箱阳极的接近程度可能有助于Ti管的氢化。建议停止使用牺牲性阴极保护,并在铸铁水箱和Muntz管板上涂环氧树脂。