首页> 外文期刊>Engineering failure analysis >Alternatives to prevent the failure of RC members under close-in blast loadings
【24h】

Alternatives to prevent the failure of RC members under close-in blast loadings

机译:防止钢筋混凝土构件在爆破载荷作用下失效的替代方案

获取原文
获取原文并翻译 | 示例

摘要

In this paper, an experimental study of the dynamic response of reinforced concrete ( RC) members protected in different ways is presented. Two alternatives for the protection of RC members are designed and studied; classical steel jacketing and a new reinforced polyurethane sacrificial layer. The mitigation of shock and absorption of energy from the blast is studied with experimental methods. For comparison purposes, a RC member without protection is also tested and studied. As expected, the steel jacketing provided excellent protection reducing the maximum final deflection as well as reducing damage to the member. On the other hand, the proposed reinforced polyurethane protection performed reasonably well. The obtained results are useful for exploring new alternatives for the protection of RC columns as well as for the calibration of numerical codes. (C) 2015 Elsevier Ltd. All rights reserved.
机译:本文对以不同方式保护的钢筋混凝土构件的动力响应进行了实验研究。设计并研究了两种保护RC成员的方法:经典钢护套和新的增强聚氨酯牺牲层。用实验方法研究了冲击波的减震和能量吸收。为了进行比较,还对无保护的RC构件进行了测试和研究。正如预期的那样,钢护套提供了出色的保护,可减少最大的最终挠度并减少对构件的损坏。另一方面,所提出的增强聚氨酯保护性能相当好。获得的结果可用于探索保护RC色谱柱的新方法以及数字标定。 (C)2015 Elsevier Ltd.保留所有权利。