Assessment of proper radial location for strain gages is extremely important in accurate experimental determination of mixed mode stress intensity factors (SIFs) and is an open problem. The present work proposes a methodology for accurate estimation of maximum permissible radial location (r_(max)) and also suggests a new strain gage method for experimental determination of the mixed mode SIFs (K_I and K_(II)). The effect of crack length to width ratio and state of stress on the r_(max) has also been investigated in this work. Numerical results obtained from the present investigation are observed to be in accordance with the theoretical predictions.
机译:应变计正确径向位置的评估在精确测定混合模式应力强度因子(SIF)的实验中极为重要,这是一个未解决的问题。本工作提出了一种精确估算最大允许径向位置(r_(max))的方法,并提出了一种新的应变计方法,用于实验确定混合模式SIF(K_I和K_(II))。在这项工作中,还研究了裂纹的长宽比和应力状态对r_(max)的影响。观察到从本研究获得的数值结果与理论预测一致。