The field reliability test conducted in the real operation conditions is the basis of water networks unreliability assessment. This kind of tests has being conducted in Poland for over 35 years. The latest results of the tests for water networks in the biggest cities in Poland have been presented in this article. Data concerning failures of the pipelines in these three cities have been gathered in the Geographical Information Systems. The unit intensity of failures ?. (failures/km year) was used for pipeline unreliability/reliability assessment. This kind of index is very useful for assessment and reliability/unreliability of different pipelines comparison. In particular the unit intensity of failures allows the preliminary assessment of pipelines technical state, which facilitates making decision about renewal of pipelines. This kind of index plays a very important role in the decision making procedure of material selection to network construction. Analysis of the intensity of failures values from the last 10 years of networks operation period showed that Polish networks unreliability decreased close to 3 times. Although the progress of failures intensity of Polish networks is much higher than intensity of failures of networks in many European countries. The influence of the main factors i.e. instability of ground, values and variability of the water pressure in network, as well as pipeline material on failure frequency of the water network was also presented in the paper.
机译:在实际运行条件下进行的现场可靠性测试是供水网络不可靠性评估的基础。这种测试已经在波兰进行了35年以上。本文介绍了波兰最大城市的供水网络测试的最新结果。有关这三个城市的管道故障的数据已在地理信息系统中收集。失效的单位强度?。 (故障/公里年)用于管道不可靠性/可靠性评估。这种指标对于评估和比较不同管道的可靠性/不可靠性非常有用。特别是故障的单位强度允许对管道的技术状态进行初步评估,这有助于做出有关管道更新的决策。这种指标在网络建设材料选择的决策过程中起着非常重要的作用。对网络运行最近十年的故障强度值的分析表明,波兰网络的不可靠性降低了近3倍。尽管波兰网络故障强度的进步程度远高于许多欧洲国家的网络故障强度。文中还提出了地面不稳定性,管网中水压的数值和变化以及管道材料等主要因素对管网故障频率的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号