The paper presents investigation of the causes of the accident which took place in the tur bogenerator hall. On the basis of the information given from the crane operator, witness and the Office of Technical Inspection report, the possible scenario of the event was recon structed. The numerical simulation and studies of the supplied documentation allowed to say that the rotor drop was a consequence of a simultaneous occurrence of a series of unfa vorable factors. The paper presents step by step the event course indicating all factors which validates assumed scenario of the accident.
机译:本文介绍了在涡轮发电机大厅发生事故的原因。根据起重机操作员,证人和技术检查办公室的报告提供的信息,重构了该事件的可能情况。所提供文档的数值模拟和研究表明,转子跌落是一系列不利因素同时发生的结果。本文逐步介绍了表明所有因素的事件过程,这些过程验证了事故的假设情景。