首页> 外文期刊>Electrochimica Acta >Insights into the simultaneous chronopotentiometric stripping measurement of indium(III), thallium(I) and zinc(II) in acidic medium at the in situ prepared antimony film carbon paste electrode
【24h】

Insights into the simultaneous chronopotentiometric stripping measurement of indium(III), thallium(I) and zinc(II) in acidic medium at the in situ prepared antimony film carbon paste electrode

机译:在原位准备的锑膜碳糊电极上同时计时电位法溶出铟(III),th(I)和锌(II)的见解

获取原文
获取原文并翻译 | 示例
           

摘要

The simultaneous measurement of microgram per liter concentration levels of indium(III), thallium(I) and zinc(II) at the antimony film carbon paste electrode (SbF-CPE) is demonstrated. The antimony film was deposited in situ on a carbon paste substrate electrode and employed in chronopotentiometric stripping mode in deoxygenated solutions of 0.01 M hydrochloric acid (pH 2). The chronopotentiometric stripping performance of the SbF-CPE was studied and compared with constant current chronopotentiometric stripping and anodic stripping voltammetric operation. In comparison with its bismuth and mercury counterparts, the SbF-CPE exhibited advantageous electroanalytical performance; namely, at the bismuth film electrode, the measurement of zinc(II) was practically impossible due to hydrogen evolution, whereas the mercury film electrode exhibited a poorly developed signal for thallium(I). The SbF-CPE revealed favorable calculated LoDs (3σ) of 1.4 μg L~(-1) for thallium(I) and 2.4 μg L~(-1) for indium(III) along with good linear response in the examined concentration range from 10 to 100 μg L~(-1) with correlations coefficients (R~2) of 0.992 for thallium(I) and 0.994 for indium(III) associated with a 120 s deposition time. The chronopotentiometric stripping performance of the SbF-CPE was characterized also by satisfactory reproducibility of 1.62% for indium(III), 3.96% for thallium(I) and 2.11% for zinc(II) (c=40 μg L~(-1), n = 11).
机译:演示了在锑膜碳糊电极(SbF-CPE)上同时测量每升铟(III),th(I)和锌(II)的微克浓度水平的方法。锑膜原位沉积在碳糊基质电极上,并以计时电位剥离法在0.01 M盐酸(pH 2)的脱氧溶液中使用。研究了SbF-CPE的计时电位溶出性能,并将其与恒流计时电位溶出和阳极溶出伏安法操作进行了比较。与铋和汞的对应物相比,SbF-CPE表现出有利的电分析性能。即,在铋膜电极上,由于析出氢,实际上不可能进行锌(II)的测量,而汞膜电极对I(I)的信号较差。 SbF-CPE对favorable(I)的计算良好的LoDs(3σ)为1.4μgL〜(-1),对铟(III)的计算得出的LoDs(3σ)为2.4μgL〜(-1),并且在所考察的浓度范围内,线性响应良好10至100μgL〜(-1),th(I)的相关系数(R〜2)为0.992,铟(III)的相关系数为0.994,且沉积时间为120 s。 SbF-CPE的计时电位溶出性能还具有令人满意的铟(III)1.62%,th(I)3.96%和锌(II)2.11%的重现性(c = 40μgL〜(-1)) ,n = 11)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号