X-ray tomography was used to investigate the discharge behavior of a zinc air battery in-operando. A special battery set-up and preparation was used in order to meet both electrochemical and tomographic requirements. The prepared battery was discharged galvanostatically and analyzed with tomographic measurements at a state of charge of 100%, 75% and 65%. End-of-life of the investigated zinc air battery is reached much earlier than the amount of active zinc particles would allow. This is attributed to an observable blockage of oxygen transport paths in the gas diffusion layer caused by increased flooding with liquid.
机译:X射线断层扫描用于研究锌空气电池在操作中的放电行为。为了满足电化学和层析成像的要求,使用了特殊的电池设置和准备。将制得的电池恒电流放电,并在100%,75%和65%的充电状态下通过X线断层摄影术进行分析。所研究的锌空气电池的使用寿命比活性锌颗粒允许的寿命要早得多。这归因于由液体溢流引起的在气体扩散层中的氧气输送路径的可观察到的阻塞。