首页> 外文期刊>Electrochemical and solid-state letters >In Situ Micro-Raman on the Membrane in a Working PEM Cell
【24h】

In Situ Micro-Raman on the Membrane in a Working PEM Cell

机译:工作中的PEM电池膜上的原位拉曼光谱

获取原文
获取原文并翻译 | 示例
           

摘要

An electrochemical cell has been designed for in situ micro-Raman measurements on the polymer membrane in an operating polymer electrolyte cell (PEM). The method is applicable to studies of both the distribution of water and membrane structure in the working cell environment. An initial study of the water distribution across a Nation 117 membrane in a cell working as a H_2 /H_2 pump cell at hydrogen flow and currents from 0 to 300 mA/cm is presented. The results show that a hydration profile with a lower water content at the anode forms as current is applied to the cell.
机译:已经设计了电化学电池,用于在运行中的聚合物电解质电池(PEM)中对聚合物膜进行原位微拉曼测量。该方法适用于研究工作单元环境中水的分布和膜结构。提出了在氢气流和0至300 mA / cm 2的电流下,作为H_2 / H_2泵电池工作的电池中Nation 117膜上水分布的初步研究。结果表明,当向电池施加电流时,会在阳极形成水含量较低的水合曲线。