首页> 外文期刊>Electrochemical and solid-state letters >Electropurification of Sulfur-Containing Sewage By Electro-oxidizing Desulfurization
【24h】

Electropurification of Sulfur-Containing Sewage By Electro-oxidizing Desulfurization

机译:电氧化脱硫对含硫污水进行电纯化

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Electropurification processing parameters,characterization, and mechanism of electro-oxidizingdesulfurization for sulfur-contanining wastewater have beeninvestigated and determined. The removal efficiency of sulfidesand chemical oxygen demand (CODcr) are 93 and 85%,respectively, in pilot test solutions containing sulfides of 1.0 and1.1 g L-1 and CODcr of 1.44-1.87 g L-1 with pH 7.0-10.0 at 30℃.The specific energy consumption of the process is 3.95 kWh (kgs)-1. The Fe2+-H2O2 oxidizing agent generated in the solution isresponsible for high efficiency desulfurization by oxidzing HS- or S2- to S.
机译:研究并确定了含硫废水的电纯化工艺参数,表征及电氧化脱硫机理。在含有1.0和1.1 g L-1的硫化物和1.44-1.87 g L-1的硫化物的pH为7.0-10.0的中试溶液中,硫化物和化学需氧量(CODcr)的去除效率分别为93和85%。 30℃。该过程的单位能耗为3.95 kWh(kgs)-1。溶液中生成的Fe2 + -H2O2氧化剂负责通过将HS-或S2-氧化为S进行高效脱硫。