首页> 外文期刊>Electroanalysis >The Application of Nafion Metal Catalyst Free Carbon Nanotube Modified Gold Electrode: Voltammetric Zinc Detection in Serum
【24h】

The Application of Nafion Metal Catalyst Free Carbon Nanotube Modified Gold Electrode: Voltammetric Zinc Detection in Serum

机译:Nafion金属催化剂游离碳纳米管修饰的金电极的应用:伏安锌在血清中的检测

获取原文
获取原文并翻译 | 示例
       

摘要

Metal catalyst free carbon nanotube (MCFCNT) whiskers were first used as an electrode modification material on a gold electrode surface for zinc voltammetric measurements. A composite film of Nafion and MCFCNT whiskers was applied to a gold electrode surface to form a mechanically stable sensor. The sensor was then used for zinc detection in both acetate buffer solution and extracted bovine serum solution. A limit of detection of 53 nM was achieved for a 120 s deposition time. The zinc in bovine serum was extracted via a double extraction procedure using dithizone in chloroform as a zinc chelating ligand. The modified electrode was found to be both reliable and sensitive for zinc measurements in both matrices.
机译:首先将不含金属催化剂的碳纳米管(MCFCNT)晶须用作金电极表面上的电极改性材料,用于锌伏安法测量。将Nafion和MCFCNT晶须的复合膜应用于金电极表面,以形成机械稳定的传感器。然后将传感器用于乙酸盐缓冲溶液和提取的牛血清溶液中的锌检测。在120 s的沉积时间内达到53 nM的检测极限。牛血清中的锌通过双萃取程序萃取,使用氯仿中的双硫zone作为锌螯合配体。发现修饰的电极对于两种基质中的锌测量都是可靠且灵敏的。