Active compensation and filtering systems have been becoming more important day by day for ensuring high quality in power generation and reducing its cost. Passive compensation and filter circuits have been replaced by SCR-based circuits as a result of development in semiconductor technology. Determining reference current for these circuits is quite important for filter and compensation circuits [1-12]. Reference current can be defined as total of all instantaneous active and reactive currents drawn due to unbalanced loads or harmonic distortions. An active compensation circuit is run in a way that it generates this reference current. Most frequently preferred methods for obtain reference current are p-q theory, Peng theory, Park Power theory etc. PWM technique is generally preferred in compensator current control [1-12]. p-q theory, which is most prevalent calculation method, was took reference in this study.
机译:主动补偿和滤波系统已日益变得越来越重要,以确保发电的高质量并降低其成本。由于半导体技术的发展,无源补偿和滤波电路已被基于SCR的电路所取代。对于滤波器和补偿电路[1-12],为这些电路确定参考电流非常重要。基准电流可以定义为由于不平衡负载或谐波失真而产生的所有瞬时有功和无功电流的总和。有源补偿电路以产生该参考电流的方式运行。获得参考电流最常用的方法是p-q理论,Peng理论,Park Power理论等。在补偿器电流控制中,PWM技术通常是优选的[1-12]。本研究参考了最流行的计算方法p-q理论。