...
首页> 外文期刊>Electrophoresis: The Official Journal of the International Electrophoresis Society >Micellar electrokinetic capillary chromatography for the determination of Viagra and its metabolite (UK-103,320) in human serum
【24h】

Micellar electrokinetic capillary chromatography for the determination of Viagra and its metabolite (UK-103,320) in human serum

机译:胶束电动毛细管色谱法测定人血清中的伟哥及其代谢物(UK-103,320)

获取原文
获取原文并翻译 | 示例
           

摘要

Micellar electrokinetic capillary chromatography (MEKC) was investigated for the determination of Viagra (sildenafil citrate, SC) and its metabolite (UK-103,320) in human serum in a concentration range of clinical interest. For MEKC, human serum samples spiked with SC and UK were obtained directly after elution with methanol from a tC18 cartridge. The extract was evaporated and regenerated in a solution 1 mM of phosphate buffer (pH 12.3) which contained a methanol percentage of 20% that was analyzed using phosphate buffer (pH 12.3, 10 mM) containing 30 mM sodium dodecyl sulfate (SDS) as separation electrolyte and a fused-silica capillary. This method gave satisfactory interday precision with respect to migration times relative standard deviation (RSD < 1%) and linear responses for the concentration ranges investigated (0.50-3.50 mg L-1 for the compound SC and 0.90-4.60 mg L-1 for UK). An intraday RSD (n = 5 graphs) between the slopes of the calibration graphs was acceptable 16.40%) for SC and (3.37%) for UK. A satisfactory interday precision between slopes was also obtained (RSD 4.10% for SC and a RSD 2.72% for UK) which demonstrated the ruggedness of this method. Detection limits (S/N = 3) were about 200 ng/mL for both compounds in human serum. MEKC was shown as a good method with regards to simplicity, precision and sensitivity. [References: 12]
机译:对胶束电动毛细管色谱法(MEKC)进行了研究,以测定具有临床意义的浓度范围的人血清中的伟哥(枸den酸西地那非,SC)和代谢物(UK-103,320)。对于MEKC,在从tC18柱上用甲醇洗脱后,直接获得掺有SC和UK的人血清样品。将萃取液蒸发并在1 mM磷酸盐缓冲液(pH 12.3)的溶液中再生,该溶液含有20%的甲醇,可使用磷酸盐缓冲液(pH 12.3,10 mM)进行分析,其中磷酸盐缓冲液(pH 12.3,10 mM)包含30 mM十二烷基硫酸钠(SDS)电解质和石英毛细管。该方法在迁移时间相对标准偏差(RSD <1%)和所研究浓度范围内的线性响应(化合物SC为0.50-3.50 mg L-1,英国为0.90-4.60 mg L-1)方面具有令人满意的日间精度。 )。校准曲线的斜率之间的日间RSD(n = 5个曲线图)对于SC可接受(16.40%),对于英国为(3.37%)。还获得了令人满意的坡度之间的日间精度(SC的RSD为4.10%,UK的RSD为2.72%),这证明了这种方法的坚固性。人血清中两种化合物的检出限(S / N = 3)约为200 ng / mL。就简单性,准确性和敏感性而言,MEKC被证明是一种很好的方法。 [参考:12]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号