首页> 外文期刊>Electrophoresis: The Official Journal of the International Electrophoresis Society >Capillary zone electrophoresis tandem mass spectrometry detects low concentration host cell impurities in monoclonal antibodies
【24h】

Capillary zone electrophoresis tandem mass spectrometry detects low concentration host cell impurities in monoclonal antibodies

机译:毛细管区带电泳串联质谱检测单克隆抗体中的低浓度宿主细胞杂质

获取原文
获取原文并翻译 | 示例
           

摘要

We have evaluated CZE-ESI-MS/MS for detection of trace amounts of host cell protein impurities in recombinant therapeutics. Compared to previously published procedures, we have optimized the buffer pH used in the formation of a pH junction to increase injection volume. We also prepared a 5-point calibration curve by spiking 12 standard proteins into a solution of a human mAb. A custom CZE-MS/MS system was used to analyze the tryptic digest of this mixture without depletion of the antibody. CZE generated a similar to 70-min separation window (similar to 90-min total analysis duration) and similar to 300-peak capacity. We also analyzed the sample using ultra-performance LC-MS/MS. CZE-MS/MS generated approximately five times higher base peak intensity and more peptide identifications for low-level spiked proteins. Both methods detected all proteins spiked at similar to 100 ppm level with respect to the antibody.
机译:我们评估了CZE-ESI-MS / MS用于检测重组治疗剂中痕量的宿主细胞蛋白质杂质。与以前发布的程序相比,我们优化了用于形成pH连接的缓冲液pH,以增加进样量。我们还通过将12种标准蛋白掺入人mAb溶液中来制备了5点校准曲线。使用定制的CZE-MS / MS系统分析该混合物的胰蛋白酶消化,而不会消耗抗体。 CZE产生了类似于70分钟的分离窗口(类似于90分钟的总分析时间)和300峰容量。我们还使用超高性能LC-MS / MS分析了样品。 CZE-MS / MS产生的基峰强度大约高五倍,而低水平加标蛋白质的肽段鉴定更多。两种方法都检测到所有相对于抗体以接近100 ppm的水平加标的蛋白质。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号