...
首页> 外文期刊>Electrophoresis: The Official Journal of the International Electrophoresis Society >Hand drawing of pencil electrodes on paper platforms for contactless conductivity detection of inorganic cations in human tear samples using electrophoresis chips
【24h】

Hand drawing of pencil electrodes on paper platforms for contactless conductivity detection of inorganic cations in human tear samples using electrophoresis chips

机译:手绘纸平台上的铅笔电极,用于通过电泳芯片检测人眼泪样品中无机阳离子的非接触式电导率

获取原文
获取原文并翻译 | 示例
           

摘要

This paper describes for the first time the fabrication of pencil drawn electrodes (PDE) on paper platforms for capacitively coupled contactless conductivity detection ((CD)-D-4) on electrophoresis microchips. PDE-(CD)-D-4 devices were attached on PMMA electrophoresis chips and used for detection of K+ and Na+ in human tear samples. PDE-(CD)-D-4 devices were produced on office paper and chromatographic paper platforms and their performance were thoroughly investigated using a model mixture containing K+, Na+, and Li+. In comparison with chromatographic paper, PDE-(CD)-D-4 fabricated on office paper has exhibited better performance due to its higher electrical conductivity. Furthermore, the detector response was similar to that recorded with electrodes prepared with copper adhesive tape. The fabrication of PDE-(CD)-D-4 on office paper has offered great advantages including extremely low cost (< $ 0.004 per unit), reduced fabrication time (< 5 min), and minimal instrumentation (pencil and paper). The proposed electrodes demonstrated excellent analytical performance with good reproducibility. For an inter-PDE comparison (n = 7), the RSD values for migration time, peak area, and separation efficiency were lower than 2.5, 10.5, and 14%, respectively. The LOD's achieved for K+, Na+, and Li+ were 4.9, 6.8, and 9.0 M, respectively. The clinical feasibility of the proposed approach was successfully demonstrated with the quantitative analysis of K+ and Na+ in tear samples. The concentration levels found for K+ and Na+ were, respectively, 20.8 +/- 0.1 mM and 101.2 +/- 0.1 mM for sample #1, and 20.4 +/- 0.1 mM and 111.4 +/- 0.1 mM for sample #2.
机译:本文首次描述了在纸制平台上制造铅笔状电极(PDE),以在电泳微芯片上进行电容耦合非接触式电导率检测((CD)-D-4)。 PDE-(CD)-D-4设备连接到PMMA电泳芯片上,用于检测人眼泪样品中的K +和Na +。 PDE-(CD)-D-4设备是在办公用纸和色谱纸平台上生产的,使用包含K +,Na +和Li +的模型混合物对性能进行了彻底研究。与色谱纸相比,在办公纸上制造的PDE-(CD)-D-4由于具有较高的电导率而具有更好的性能。此外,检测器的响应类似于用铜胶带制备的电极记录的响应。在办公用纸上制造PDE-(CD)-D-4提供了很多优势,包括极低的成本(每单位<0.004美元),减少的制造时间(<5分钟)以及最少的仪器(铅笔和纸)。拟议的电极表现出出色的分析性能和良好的重现性。对于PDE间的比较(n = 7),迁移时间,峰面积和分离效率的RSD值分别低于2.5%,10.5和14%。 K +,Na +和Li +的LOD分别为4.9 M,6.8 M和9.0M。通过定量分析眼泪样品中的K +和Na +,成功地证明了该方法的临床可行性。样品#1的K +和Na +的浓度水平分别为20.8 +/- 0.1 mM和101.2 +/- 0.1 mM,样品#2的浓度水平为20.4 +/- 0.1 mM和111.4 +/- 0.1 mM。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号