首页> 外文期刊>Electrophoresis: The Official Journal of the International Electrophoresis Society >SYSTEM PEAKS IN CAPILLARY ZONE ELECTROPHORESIS .3. PRACTICAL RULES FOR PREDICTING THE EXISTENCE OF SYSTEM PEAKS IN CAPILLARY ZONE ELECTROPHORESIS OF ANIONS USING INDIRECT SPECTROPHOTOMETRIC DETECTION
【24h】

SYSTEM PEAKS IN CAPILLARY ZONE ELECTROPHORESIS .3. PRACTICAL RULES FOR PREDICTING THE EXISTENCE OF SYSTEM PEAKS IN CAPILLARY ZONE ELECTROPHORESIS OF ANIONS USING INDIRECT SPECTROPHOTOMETRIC DETECTION

机译:毛细管区带电泳中的系统峰值.3。间接分光光度法预测阴离子毛细管电泳中系统峰存在的实用规则

获取原文
获取原文并翻译 | 示例
           

摘要

A theoretical and experimental study of the existence and evolution of system peaks in capillary zone electrophoresis (CZE) with indirect spectrophotometric detection is presented with respect to the effect of the number of colons present in the background electrolyte (BGE). It is shown that in BGEs having only one colon (i.e., the UV-absorbing probe anion), the sample produces only negative peaks due to each analyte anion and no system peaks, with the number of sample peaks corresponding to the number of analytes present in the sample injected. In BGEs containing two colons, a sample with one analyte anion produces one negative indirect detection peak and one system peak. The transition between BGEs having one colon and those with two colons has also been studied and it has been shown that an addition of ca. 5% of the second colon to a single colon BGE causes the resulting BGE to behave macroscopically as a regular two-colon BGE. A descriptive model is proposed, based on transient isotachophoresis (transient stacking) of the sample species and of the colon from the BGE which has the closest mobility to the sample ion. This model explains qualitatively the formation and evolution of the sample peak (containing the sample species and being detected by indirect detection due to displacement of the UV-absorbing probe in its zone) and the system peak (containing no sample species and being a vacancy in the continuum of colons of the BGE). It is shown that the system peak may be positive or negative as it corresponds to the situation where the vacancy of one component of the BGE results in an enhanced concentration of the other component. It has been demonstrated that the system peak is created by a vacancy of that component of the BGE which has the greatest difference in mobility relative to that of the sample species. On indirect detection in BGEs containing two colons the sample displaces predominantly the BGE colon which has a mobility closest to that of the analyte anion. In systems with BGEs containing two colons, a sample having n analytes produces n sample peaks and one system peak, the sign and magnitude of which are dependent on the sum of the UV absorbances of the analytes involved. The effect of bicarbonate from atmospheric CO2 has also been studied and it has been shown that weakly alkaline BGEs with a single anionic UV-absorbing colon, such as those currently used for anionic analyses with indirect detection, may suffer from the presence of system peaks due to bicarbonate. [References: 22]
机译:相对于背景电解质(BGE)中存在的结肠数目的影响,利用间接分光光度法检测对毛细管区带电泳(CZE)中系统峰的存在和演化进行了理论和实验研究。结果表明,在仅具有一个冒号(即吸收紫外线的探针阴离子)的BGE中,样品由于每种分析物阴离子仅产生负峰,而没有系统峰,样品峰的数量与存在的分析物的数量相对应在进样中。在包含两个冒号的BGE中,具有一种分析物阴离子的样品会产生一个负的间接检测峰和一个系统峰。还研究了具有一个冒号的BGE和具有两个冒号的BGE之间的过渡,结果表明,添加了大约3个CGE。单个结肠BGE的第二个结肠的5%会使生成的BGE在宏观上表现为规则的两个冒号BGE。根据样品物种和来自BGE的结肠的瞬时等速电泳(瞬态堆积),提出了一种描述性模型,该BGE具有最接近样品离子的迁移率。该模型定性地解释了样品峰(包含样品种类,并且由于紫外线吸收探针在其区域内的位移而通过间接检测进行检测)和系统峰(不包含样品种类并且在样品中存在空位)的形成和演化。 BGE结肠的连续体)。结果表明,系统峰可能为正也可能为负,因为它对应于BGE中一种组分的空位导致另一种组分的浓度升高的情况。已经证明系统峰是由BGE组分的空位产生的,该空位相对于样品物种的迁移率具有最大差异。在含有两个冒号的BGE中进行间接检测时,样品主要取代了BGE结肠,其迁移率最接近分析物阴离子。在具有包含两个冒号的BGE的系统中,具有n个分析物的样品会产生n个样品峰和一个系统峰,其峰号和大小取决于所涉及分析物的UV吸光度之和。还研究了来自大气CO2的碳酸氢盐的影响,结果表明,带有单个阴离子紫外线吸收结肠的弱碱性BGE,例如目前用于间接检测阴离子分析的那些,可能会由于存在系统峰而受到影响。重碳酸盐。 [参考:22]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号