The protection of overhead transmission lines from lightning strokes is one of the most important tasks of safeguarding electric power systems. In order to do this job effectively, the lightning performance of the transmission lines has to be evaluated accurately. This paper presents the development of a method for estimating the shielding failure number of power transmission lines in different configurations by using the charge-simulation method. The effects of towers, sags of conductors, and a perfectly conducting ground are represented in a 3-D computation. In addition, the stepwise descending nature of a downward negative leader-streamer systems is taken into account by using an appropriate progression model. Upward leader inception and propagation is also modeled utilizing critical equivalent streamer-length criterion. The method is applied to compute the shielding failure of power transmission line for different configurations.
机译:保护架空输电线路免受雷击是保护电力系统的最重要任务之一。为了有效地完成这项工作,必须准确评估传输线的防雷性能。本文提出了一种利用电荷模拟方法估算不同配置的输电线路屏蔽故障次数的方法的发展。塔的影响,导体的下垂和完美导电的地面在3-D计算中得以体现。另外,通过使用适当的渐进模型考虑了向下负领导者-拖缆系统的逐步下降性质。还使用临界等效拖缆长度准则对上行领导者的起始和传播进行建模。该方法适用于计算不同配置的输电线路的屏蔽故障。