首页> 外文期刊>International Journal of Mining and Mineral Engineering >CFD modelling of sampling locations for early detection of spontaneous combustion in long-wall gob areas
【24h】

CFD modelling of sampling locations for early detection of spontaneous combustion in long-wall gob areas

机译:用于长壁采空区自发燃烧早期检测的采样位置的CFD建模

获取原文
获取原文并翻译 | 示例
       

摘要

In this study, computational fluid dynamics (CFD) modeling was conducted to optimize gas sampling locations for the early detection of spontaneous heating in longwall gob areas. Initial simulations were carried out to predict carbon monoxide (CO) concentrations at various regulators in the gob using a bleeder ventilation system. Measured CO concentration values at these regulators were then used to calibrate the CFD model. The calibrated CFD model was used to simulate CO concentrations at eight sampling locations in the gob using a bleederless ventilation system to determine the optimal sampling locations for early detection of spontaneous combustion.
机译:在这项研究中,进行了计算流体动力学(CFD)建模,以优化气体采样位置,以便长壁采空区自发加热的早期检测。使用放气通风系统进行了初步模拟,以预测采空区各个调节器处的一氧化碳(CO)浓度。然后将在这些调节器上测得的CO浓度值用于校准CFD模型。校准的CFD模型用于使用无排气通风系统来模拟采空区中八个采样位置的一氧化碳浓度,从而确定用于自发燃烧早期检测的最佳采样位置。