首页> 外文期刊>Bulletin du Cancer: Journal de l'Association Francaise pour l'Etude du Cancer >Breast implants and health alert PIP: Experience of the regional cancer center of Lille [Alerte sanitaire et implants mammaires PIP: Expérience du centre régional de lutte contre le cancer de Lille]
【24h】

Breast implants and health alert PIP: Experience of the regional cancer center of Lille [Alerte sanitaire et implants mammaires PIP: Expérience du centre régional de lutte contre le cancer de Lille]

机译:乳房植入物和健康预警PIP:里尔地区癌症中心的经验

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction. On March 30, 2010, Afssaps issued a health alert concerning breast implants brand PIP, after identifying a rupture rate higher than for other manufacturers. This alert asking the recall of all concerned patients with, according to the clinical examination, ultrasound and the desire of the patient, the possibility of explantation. We focus on PIP implanted in Oscar- Lambret center in Lille. Materials and patients. A retrospective study on all patients carrying breast prosthesis PIP implanted in the Oscar-Lambret center. We are interested in the rate of patients who chose clinical and ultrasound monotoring, explantation rates, and prosthetic rupture. Results. Thirty-three PIP (in 31 patients) have been implanted in the center between May 2, 2006 and March 9, 2010. The mean age of implants was 15.35 months. We realized eight explants, and found three intracapsular rupture. Two of three rupture were symptomatic. Conclusion. The majority of patients chose surveillance. Our short series does not give precise information about their risk of prosthetic failure, a national register should be established. The literature illustrates the low sensitivity of ultrasonography in the diagnosis of intracapsular rupture and the superiority of MRI. In the context of a health alert, could we propose a monitoring tool implant breast MRI in order to minimize the rate of patients carrying a ruptured implant (false negative).
机译:介绍。 2010年3月30日,Afssaps确定了高于其他制造商的破裂率,并发布了有关乳房植入物品牌PIP的健康警报。该警报要求召回所有相关患者,根据临床检查,超声检查和患者的意愿,进行移植的可能性。我们专注于在里尔的Oscar- Lambret中心植入的PIP。材料和病人。一项对所有在奥斯卡-兰伯雷特中心植入乳房假体PIP的患者进行的回顾性研究。我们对选择临床和超声monotoring的患者比率,外植率和假体破裂感兴趣。结果。在2006年5月2日至2010年3月9日期间,已在中心植入了33个PIP(共31例患者)。植入物的平均年龄为15.35个月。我们实现了8个外植体,并发现了3个囊内破裂。三分之二的破裂是有症状的。结论。大多数患者选择了监视。我们的简短系列文章并未提供有关其假体失败风险的准确信息,应建立国家注册机构。文献说明了超声检查在囊内破裂诊断中的低敏感性以及MRI的优越性。在发出健康警报的情况下,我们可以提出一种监视工具植入物乳房MRI,以最大程度地减少植入物破裂(假阴性)的患者的发生率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号