...
首页> 外文期刊>Echocardiography. >Right atrial indexed volume in healthy adult population: Reference values for two-dimensional and three-dimensional echocardiographic measurements
【24h】

Right atrial indexed volume in healthy adult population: Reference values for two-dimensional and three-dimensional echocardiographic measurements

机译:健康成人人群的右心房索引体积:二维和三维超声心动图测量的参考值

获取原文
获取原文并翻译 | 示例
           

摘要

Background Current guidelines do not recommend routine assessment of right atrial volume due to the lack of standardized data. Three-dimensional wall-motion tracking (3D-WMT) is a new technology that allows us to calculate volumes without any geometric assumptions. The aim of this study was to define the indexed reference values for two-dimensional echocardiography (2D-echo) and 3D-WMT in adult healthy population and to assess the intermethod, intra- and interobserver agreement. Methods Prospective study. Nonselected healthy subjects were enrolled. Every patient underwent a 2D-echo and a 3D-WMT examination. 2D-echo right atrial volume was obtained by using the area-length method (A-L) from four- and two-chamber view. 3D-echo volumes were assessed by 3D-WMT. Values were indexed by the patient's body surface area. Results Sixty consecutive healthy subjects were enrolled. Mean age was 57 ± 12-years old and 27 patients (45%) were male. Average indexed right atrial volume obtained by 2D-echo and 3D-echo was 16.76 ± 8.15 mL/m2 and 19.05 ± 6.87 mL/m2, respectively. Univariate linear regression analysis between 2D-echo and 3D-echo right atrial volumes shows a weak correlation between right atrial volume obtained with 2D-echo compared with 3D-WMT (r = 0.29, CI 95% 0.029-0.66, P = 0.033). The agreement analysis shows a similar result (intraclass correlation coefficient [ICC] = 0.28). The intra- and interobserver agreement analysis showed a better agreement when using 3D-WMT. Conclusions This is the first study that reports the reference indexed right atrial volume values by means of 2D-echo and 3D-echo in healthy population. 3D-WMT is a feasible and reproducible method to determine right atrial volume.
机译:背景技术由于缺乏标准化的数据,当前指南不建议对右心房容量进行常规评估。三维墙运动跟踪(3D-WMT)是一项新技术,使我们无需任何几何假设即可计算体积。这项研究的目的是为成人健康人群定义二维超声心动图(2D-echo)和3D-WMT的索引参考值,并评估方法间,观察者间和观察者间的一致性。方法进行前瞻性研究。纳入未选择的健康受试者。每位患者均接受了2D回波和3D-WMT检查。从四室和二室视图使用面积长度法(A-L)获得2D回波右房容积。通过3D-WMT评估3D回波体积。值由患者的体表面积索引。结果连续纳入了60名健康受试者。平均年龄为57±12岁,男性27例(45%)。通过2D回波和3D回波获得的平均分度右心房容积分别为16.76±8.15 mL / m2和19.05±6.87 mL / m2。 2D回波和3D回波右房容积之间的单变量线性回归分析显示,与3D WMT相比,使用2D回波获得的右房容积之间的相关性较弱(r = 0.29,CI 95%0.029-0.66,P = 0.033)。一致性分析显示了相似的结果(类内相关系数[ICC] = 0.28)。观察者之间和观察者之间的协议分析表明,使用3D-WMT时可以达成更好的协议。结论这是第一项报告健康人群中通过2D回波和3D回波参考的右房体积参考值的研究。 3D-WMT是确定右房容量的一种可行且可重复的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号