Are microbubbles free flowing tracers through the Myocardium? Comparison of indicator-dilution curves obtained from dye dilution and echo contrast using harmonic power Doppler imaging.

机译:微气泡是否可以自由地流过心肌?使用谐波功率多普勒成像技术从染料稀释和回声对比度获得的指示剂稀释曲线的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Harmonic power Doppler imaging (H-PDI) has been introduced into the field of contrast echocardiography as a contrast-specific imaging modality. However, there has been considerable skepticism as to whether H-PDI would be quantifiable, because it depends on the destruction of microbubbles and has more complex signal processing than gray scale imaging. The aim of the present study was to evaluate the relationship between the concentration of microbubbles and the resulting H-PDI signals even under conditions where bubble destruction is most likely. Furthermore, we evaluated whether microbubbles of Levovist freely pass the microcirculation, which is a prerequisite for the assessment of myocardial blood flow. METHODS AND RESULTS: A strong positive correlation was found between the H-PDI signals and the amount of microbubbles up to the onset of acoustic shadowing (r = 0. 968, P<0.001). Time-intensity curves for H-PDI of air-filled microbubbles were compared with time-concentration curves of indocyanine green (ICG) in both a flow phantom and a working heart setup. The mean transit times (MTTs) through the myocardium of both agents were compared after a bolus injection into the left coronary artery. A close correlation was observed between 1/MTT and flow in both setups (r>0.98, P<0.0001). However, at high flow rates, the MTTs of the microbubbles were slightly, albeit not significantly, faster than those of indocyanine green. CONCLUSIONS: We conclude that microbubbles fulfill the prerequisites of free flowing tracers through the myocardium. Furthermore, H-PDI technology allows a reliable assessment of time-concentration curves of air-filled microbubbles up to the onset of acoustic shadowing.
机译:背景:谐波功率多普勒成像(H-PDI)已作为对比特定的成像方式被引入对比超声心动图领域。但是,人们对H-PDI是否可量化表示了极大的怀疑,因为它取决于微气泡的破坏并且比灰度成像具有更复杂的信号处理。本研究的目的是评估即使在极有可能破坏气泡的条件下,微气泡的浓度与所产生的H-PDI信号之间的关系。此外,我们评估了Levovist的微气泡是否自由通过微循环,这是评估心肌血流的先决条件。方法和结果:在H-PDI信号与直至声影阴影开始的微气泡数量之间存在很强的正相关性(r = 0. 968,P <0.001)。在流动体模和工作心脏装置中,将充气微气泡的H-PDI的时间强度曲线与吲哚菁绿(ICG)的时间浓度曲线进行了比较。在推注左冠状动脉后比较两种药物通过心肌的平均通过时间(MTT)。在两种设置下,1 / MTT与流量之间都存在密切的相关性(r> 0.98,P <0.0001)。但是,在高流速下,微泡的MTT比吲哚菁绿的MTT稍快,尽管不明显。结论:我们得出的结论是,微泡满足通过心肌自由流动的示踪剂的先决条件。此外,H-PDI技术可以可靠地评估充气微泡直至声影阴影开始的时间-浓度曲线。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号