...
首页> 外文期刊>Ecological engineering: The Journal of Ecotechnology >Effects of load fluctuations on treatment potential of a hybrid sub-surface flow constructed wetland treating milking parlor waste water
【24h】

Effects of load fluctuations on treatment potential of a hybrid sub-surface flow constructed wetland treating milking parlor waste water

机译:负荷波动对混合地下水流人工湿地处理挤奶厅废水的处理潜力的影响

获取原文
获取原文并翻译 | 示例
           

摘要

A hybrid sub-surface constructed wetland (CW) system consisting of 2 gravel filled vertical subsurface (VFa & VFb) beds, each 160 m~(-2) in size planted with Phragmkes australis and a sand filled horizontal sub-surface (HF) bed, 336 m~(-2) in size, planted with rice was operated from 2007 to 2010 for treating milking parlor waste water in Hokkaido, Japan. Hybrid CW system received huge fluctuations in average yearly inlet loads for TSS (526.0-l259mgL~(-1) & 2.7-9.0gm~(-2)d~(-1)), BOD5 (l,080-2,114mgL~(-1) & 8.4-14.4gm~(-2)d~(-1)), COD(1,962-7,085 mgL~(-1) & l4.5-50.0gm~(-2)d~(-1)), TN (116.0-243.0 mgL~(-1) & 0.8-1.6gm~(-2)d~(-1)), NH4-N (54.0-90.0 mgL~(-1) & 0.40-0.64gm~(-2)d~(-1)), TC (1,022-2,215mgL~(-1) & 6.0-15.1 gm~(-2)d~(-1)), TP (15.3-41.7mgL~(-1) & 0.11 -0.28 gm~(-2) d~(-1)) during study period. Average yearly purification and removal rates were least fluctuated for TSS (95.7-99.4%); moderately for BOD5 (86.1 -95.7%), COD(87.5-96.1 %) and TC (79.5-91.3%); highly for TN (72.6-90.6%), NH4-N (62.9-85.3%) and TP (64.8-87.2%). A sharp decrease in TP purification and removal rates were observed in 2008 due to sharp decrease in influent TP concentration in 2008 compared to 2007. OTR values for VF(a), VF(b), HF bed and total system were observed as 21.7,19.3,4.8 and 12.3 g O2 m~(-2) d~(-1) respectively. Average k value of hybrid CW system for BOD5, TN, NH4-N and TP during study period were 7.0 ± 1.8, 7.4 ± 3.3,5.6 ± 4.1 and 4.9 ± 2.0 m yr~(-1) respectively. Average concentration of TSS, TP, TN and NH4-N in the final effluent for all years were below the discharge limit value of: 150mgL~(-1) for TSS; 8mgL~(-1) for TP, 60mgL~(-1) for TN and NH4-N. However, average BOD5 and COD concentrations could not meet the discharge limit value of 120mgL~(-1) during 2007 and 2008.
机译:一种混合的地下人工湿地(CW)系统,由2个砾石填充的垂直地下(VFa和VFb)床组成,每张床的大小为160 m〜(-2),其中种植了澳洲芦苇和沙子填充的水平地下(HF)从2007年到2010年,在日本北海道经营了336 m〜(-2)的水稻种植床,用于处理挤奶厅废水。混合式CW系统的TSS年平均进口负荷(526.0-l259mgL〜(-1)和2.7-9.0gm〜(-2)d〜(-1)),BOD5(l,080-2,114mgL〜( -1)和8.4-14.4gm〜(-2)d〜(-1)),COD(1,962-7,085 mgL〜(-1)和l4.5-50.0gm〜(-2)d〜(-1) ),TN(116.0-243.0 mgL〜(-1)和0.8-1.6gm〜(-2)d〜(-1)),NH4-N(54.0-90.0 mgL〜(-1)和0.40-0.64gm〜 (-2)d〜(-1)),TC(1,022-2,215mgL〜(-1)和6.0-15.1 gm〜(-2)d〜(-1)),TP(15.3-41.7mgL〜(- 1)和研究期间的0.11 -0.28 gm〜(-2)d〜(-1))。 TSS的年平均净化率和去除率波动最小(95.7-99.4%); BOD5(86.1 -95.7%),COD(87.5-96.1%)和TC(79.5-91.3%)为中等; TN(72.6-90.6%),NH4-N(62.9-85.3%)和TP(64.8-87.2%)较高。由于2008年进水TP浓度与2007年相比急剧下降,2008年TP净化和去除率急剧下降。VF(a),VF(b),HF床和整个系统的OTR值为21.7,分别为19.3,4.8和12.3 g O2 m〜(-2)d〜(-1)。研究期间BOD5,TN,NH4-N和TP的混合CW系统的平均k值分别为7.0±1.8、7.4±3.3、5.6±4.1和4.9±2.0 m yr〜(-1)。所有年份最终排放物中TSS,TP,TN和NH4-N的平均浓度均低于排放限值:TSS的排放限值为150mgL〜(-1); TP为8mgL〜(-1),TN和NH4-N为60mgL〜(-1)。然而,在2007年和2008年,BOD5和COD的平均浓度不能达到120mgL〜(-1)的排放极限值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号