首页> 外文期刊>Iranian journal of radiation research : >Assessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)
【24h】

Assessment of patients skin dose undergoing coronary angiography and Percutaneous Transluminal Coronary Angioplasty (PTCA)

机译:评估接受冠状动脉造影和经皮腔内冠状动脉成形术(PTCA)的患者皮肤剂量

获取原文
获取原文并翻译 | 示例

摘要

Background: Practice of interventions I cardiology procedures such as Coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) has largely increased in recent years and is now changing to a matter of routine in many hospitals. The purpose of this study was to measure skin and organ doses in patients undergoing CA and PTCA and to find a probable relation with cardiologist's work experience. Materials and Methods: A group of 57 patients who were admitted to Nour and Chamran hospitals, Isfahan, Iran, either for CA (n=37) or PTCA (n=20) was checked for skin, eyes and thyroid gland radiation dose. Skin dose measurement was carried out with thermoluminescent dosimeters (TLD-1OO) placed at three different positions on the patients' bodies. Also the thyroid and eye doses were measured using the same procedure. Results: Mean median, standard deviation and maximum doses for these results are presented. Maximum values found for skin in CA, PTCA, thyroid gland and eyes were 41.00, 73.90, 3.10 and 1.43 cGy, respectively. Average exposure time for CA and PTCA was 4.2?6 and 10.8?2 minutes, respectively. Radiation dose to the critical areas in each procedure in addition to its relation to the type of procedure was studied. Correlation between maximum skin dose and cardiologists' work experience was also investigated. Conclusion: 85% of the cases in CA and 78% of cases in PTCA received maximum skin dose of lower than 25cGy well below the threshold of 2 Gy suggestions for transient erythema. Iran.
机译:背景:干预措施的实践近年来,诸如冠状动脉造影(CA)和经皮腔内冠状动脉成形术(PTCA)之类的心脏病学程序已大大增加,现在在许多医院中已成为常规。这项研究的目的是测量接受CA和PTCA的患者的皮肤和器官剂量,并寻找可能与心脏病专家的工作经验相关的方法。材料和方法:一组57例因CA(n = 37)或PTCA(n = 20)入院于伊朗伊斯法罕的Nour and Chamran医院的患者的皮肤,眼睛和甲状腺辐射剂量进行了检查。皮肤剂量测量是通过将热剂量计(TLD-1OO)放置在患者身体上的三个不同位置进行的。甲状腺和眼睛的剂量也用相同的方法测量。结果:显示了这些结果的平均中位数,标准差和最大剂量。在CA,PTCA,甲状腺和眼睛中皮肤的最大值分别为41.00、73.90、3.10和1.43 cGy。 CA和PTCA的平均暴露时间分别为4.2?6和10.8?2分钟。除了与程序类型有关外,还研究了每个程序中关键区域的辐射剂量。还研究了最大皮肤剂量与心脏病专家的工作经验之间的关系。结论:CA中85%的病例和PTCA中78%的病例接受的最大皮肤剂量低于25cGy,远低于短暂性红斑2 Gy建议阈值。伊朗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号