Creep deformation of ductile cast iron cooling staves

机译:球墨铸铁冷却壁的蠕变变形

获取原文
获取原文并翻译 | 示例
           

摘要

In order to investigate the operating life of ductile cast iron cooling staves at high temperatures, high temperature tensile creep tests were carried out. The creep parameters A, m and n of the cast iron at different temperatures were obtained. The effects of gas temperature, slag skin and edge contact pressure on the creep deformation of cast iron cooling staves and cooling water pipes at high temperatures were quantitatively analysed by ABAQUS finite element program, coupled thermal/structural analysis and thermal tests in order to provide a theoretical basis for improving stave structural design, controlling creep deformation and proper installation and use of cooling staves.
机译:为了研究球墨铸铁冷却壁在高温下的使用寿命,进行了高温拉伸蠕变试验。得到了不同温度下铸铁的蠕变参数A,m和n。利用ABAQUS有限元程序,热/结构分析和热试验对气体温度,炉渣表皮和边缘接触压力对高温下铸铁冷却壁和冷却水管的蠕变变形的影响进行了定量分析,以提供一个改善冷却壁结构设计,控制蠕变变形以及正确安装和使用冷却冷却壁的理论基础。