Infusion versus bolus of an ultrasound contrast agent: in vivo dose-response measurements of BR1.

机译:超声造影剂的输注与推注:BR1的体内剂量反应测量。

获取原文
获取原文并翻译 | 示例
           

摘要

RATIONALE AND OBJECTIVES: To determine the efficacy of an ultrasound contrast agent infusion using Doppler intensitometry estimation of backscatter enhancement in blood. METHODS: Multiple intravenous injections of BR1 (SonoVue) were performed in chronic dog studies, using bolus (0.05-2 mL) and infusion (3-40 mL/h during 6 minutes) administration. The pulsed Doppler signal from the femoral artery was recorded and analyzed for mean Doppler power and integrated fractional enhancement. RESULTS: For bolus injection, time-intensity curves exhibited a rapid first pass (peak 30 dB for 0.45 mL) followed by a slower washout. Integrated fractional enhancement exhibited a linear relation with the dose (R2 = 0.99). For infusion administration, peak enhancement increased with the infusion rate from 8 to 22 dB. At rates exceeding 30 mL/h, the enhancement was stable with a plateau-like pattern. CONCLUSIONS: Infusion of BR1 is easily achieved and allows the duration of enhancement to be increased as long as desired. Stable enhancement is obtained for rates greater than 30 mL/h.
机译:理由和目的:为了确定超声造影剂输注的功效,使用多普勒强度测定法估计血液中的反向散射增强。方法:在慢性狗研究中多次静脉注射BR1(SonoVue),使用大剂量(0.05-2 mL)和输注(6分钟内3-40 mL / h)给药。记录来自股动脉的脉冲多普勒信号并分析其平均多普勒功率和积分分数增强。结果:对于大剂量注射,时间强度曲线显示出快速的第一遍(0.45 mL峰为30 dB),随后洗脱较慢。积分分数增强与剂量呈线性关系(R2 = 0.99)。对于输注给药,峰值增强随着输注速率从8 dB增加到22 dB。在超过30 mL / h的速度下,增强效果稳定且呈平台状。结论:BR1的注入很容易实现,并且可以根据需要延长增强的持续时间。对于大于30 mL / h的速率,可以获得稳定的增强。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号