首页> 外文期刊>Investigative radiology >Indirect mr arthrography of the knee: effects of low-intensity ultrasound on the diffusion rate of intravenously administered gd-dtpa in healthy volunteers.
【24h】

Indirect mr arthrography of the knee: effects of low-intensity ultrasound on the diffusion rate of intravenously administered gd-dtpa in healthy volunteers.

机译:膝关节间接磁共振成像:低强度超声对健康志愿者静脉内施用gd-dtpa扩散速率的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

Weishaupt D, Schweitzer ME, Rawool NM, et al. Indirect MR arthrography of the knee: Effects of low-intensity ultrasound on the diffusion rate of intravenously administered Gd-DTPA in healthy volunteers. Invest Radiol 2001;36:493-499.RATIONALE AND OBJECTIVES: To evaluate whether application of low-intensity ultrasound may increase the diffusion rate of intravenously administered gadopentetate dimeglumine (Gd-DTPA) and increase the amount of joint fluid on indirect magnetic resonance (MR) arthrography. METHODS: Conventional MR imaging, indirect MR arthrography, and power Doppler ultrasonography were performed before and after application of therapeutic, pulsed low-intensity ultrasound in 12 asymptomatic knees of 12 volunteers. Intra-articular diffusion of intravenously administered Gd-DTPA as measured by signal intensity differences of the intra-articular joint fluid before and after ultrasound treatment was assessed. In addition, the amount of joint fluid was rated, and differences in synovial blood flow as evidenced by power Doppler ultrasonography were noted. RESULTS: All volunteers tolerated well the application of therapeutic low-intensity ultrasound. A significant increase in intra-articular diffusion of intravenously administered Gd-DTPA was noted in all knees, and an increase in joint fluid was noted in 8 of 12 knees (66.6%). Detection of power Doppler flow signal in the synovium of the suprapatellar recess was possible in one instance at posttreatment exam. CONCLUSIONS: Use of pulsed, therapeutic low-intensity ultrasound may increase the diffusion rate of intravenously administered Gd-DTPA and may induce joint effusion.
机译:Weishaupt D,Schweitzer ME,Rawool NM等。膝关节间接MR成像:低强度超声对健康志愿者静脉内施用Gd-DTPA扩散速率的影响。 Invest Radiol 2001; 36:493-499。合理性和目的:评价低强度超声的应用是否可以提高静脉内施用的g戊二酸二聚葡胺(Gd-DTPA)的扩散率并增加间接磁共振引起的关节液量( MR)关节造影。方法:在12名志愿者的12例无症状膝关节应用治疗性脉冲低强度超声治疗前后,均进行了常规MR成像,间接MR关节造影和功率多普勒超声检查。通过超声治疗前后关节内关节液的信号强度差异来评估静脉内施用的Gd-DTPA的关节内扩散。此外,对关节液的量进行了评估,并记录了由动力多普勒超声检查所证实的滑膜血流的差异。结果:所有志愿者对治疗性低强度超声的耐受性良好。在所有膝盖中,静脉内施用的Gd-DTPA的关节内扩散均明显增加,在12个膝盖中的8个膝盖中,关节液增加(66.6%)。在后处理检查中,有可能在一种情况下检测到recess上滑膜滑膜中的功率多普勒血流信号。结论:使用脉冲治疗性低强度超声可能会增加静脉内施用Gd-DTPA的扩散速率,并可能诱发关节积液。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号