...
首页> 外文期刊>Investigative radiology >Enhanced detection of blood flow in the normal canine prostate using an ultrasound contrast agent.
【24h】

Enhanced detection of blood flow in the normal canine prostate using an ultrasound contrast agent.

机译:使用超声造影剂增强对正常犬前列腺中血流的检测。

获取原文
获取原文并翻译 | 示例

摘要

RATIONALE AND OBJECTIVES: To evaluate the sonographic appearance of normal prostate vascularity in dogs before and after injection of a new ultrasound contrast agent, NC100100. METHODS: Thirty-five intravenous injections of NC100100, in doses ranging from 0.00625 to 0.05 microL microbubbles/kg, were administered to seven anesthetized mongrel male dogs. Transrectal color Doppler imaging and power Doppler imaging were used to perform the assessment. The visibility of the vascular pattern of the prostate was assessed, including dynamics of contrast inflow, blood flow symmetry, and duration times. RESULTS: Before contrast administration, the vascular pattern was poorly visualized in all cases. After contrast injection, the visibility of the vascular architecture improved significantly for both modalities. Independent of the imaging method used, higher doses tended to be more effective than lower doses. Contrast kinetics in the prostate vessels was demonstrated with a mean time from injection of the ultrasound contrast agent to enhancement of the Doppler signals in the subcapsular arteries (+/-1 SD) of 13+/-3 seconds, and the ultrasound contrast agent reached the central periurethral veins 3 to 6 seconds later. A spokelike radial pattern of internal prostatic vessels observed with enhanced ultrasound could also be seen on silicone microfil x-ray images. The Doppler enhancement persisted for a mean time ( +/-1 SD) of 904 seconds (approximately 15 minutes) +/- 225 seconds and tended to increase with increasing dose. CONCLUSIONS: NC100100 significantly improves the detection of blood flow in the normal canine prostate and allows more accurate depiction of the vascular architecture of the prostate.
机译:理由和目的:评估在注射新的超声造影剂NC100100前后狗的正常前列腺血管超声检查的表现。方法:对七只麻醉的杂种雄性狗进行了35次静脉内NC100100静脉注射,剂量范围为0.00625至0.05 microL微气泡/ kg。经直肠彩色多普勒成像和功率多普勒成像进行评估。评估了前列腺血管模式的可见性,包括造影剂流入动态,血流对称性和持续时间。结果:在进行对比剂管理之前,所有病例的血管模式均显示不佳。对比剂注射后,两种方式的血管结构的可见度均得到显着改善。与使用的成像方法无关,较高的剂量往往比较低的剂量更有效。从注射超声造影剂到包膜下动脉多普勒信号增强(+/- 1 SD)的平均时间为13 +/- 3秒,证明了前列腺血管的对比动力学。尿道中央静脉3至6秒后。在硅胶microfil X射线​​图像上也可以看到用增强的超声观察到的内部前列腺血管的辐状放射状。多普勒增强持续了904秒(约15分钟)+/- 225秒的平均时间(+/- 1 SD),并且随着剂量的增加而趋于增加。结论:NC100100显着改善了正常犬前列腺中血流的检测,并可以更精确地描绘前列腺的血管结构。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号