首页> 外文期刊>International wood products journal >Ultrasonic technique for evaluation of bio-defects in wood: Part 1 - Influence of the position, extent and degree of internal artificial rots.
【24h】

Ultrasonic technique for evaluation of bio-defects in wood: Part 1 - Influence of the position, extent and degree of internal artificial rots.

机译:评价木材中生物缺陷的超声技术:第1部分-内部人工腐烂的位置,程度和程度的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

Artificial rots were created in Norway spruce beams 80x80x300, 120x120x300 and 150x150x300 mm by making notches of six various widths, and then by filling these notches with spruce sawdust, modelling two degrees of rot. The velocity of ultrasonic wave (UW) in the transverse direction was measured at three positions (first through notch, second through boundary of notch and non-attacked wood and third through undamaged wood), at a total of 15 locations for each beam. The UW propagation was significantly influenced by the position of transducers towards notches. In the first position, it decreased by 35-73% (on 450-1100 m s-1), in the second position by 6-10% (approximately on 1650 m s-1), while in the third position, it corresponded to original beams. In the most sensitive first position, UW velocities decreased more apparently at bigger notches. However, filling of notches with spruce sawdust had negligible effect for propagation of UW.
机译:在挪威制造云杉横梁80x80x300、120x120x300和150x150x300 mm的人造腐烂,方法是制作六个不同宽度的凹口,然后用云杉木屑填充这些凹口,以模拟两个角度的腐烂。在每个波束的总共15个位置的三个位置(第一到切口,第二到切口和未受攻击的木材的边界以及第三到未损坏的木材的边界)测量了横向超声波速度(UW)。 UW传播受换能器朝向切口的位置的影响很大。在第一位置,它降低了35-73%(在450-1100 ms -1 上),在第二位置,它降低了6-10%(大约在1650 ms -1 ),而在第三位置时,它对应于原始光束。在最敏感的第一位置,UW速度在更大的缺口处明显下降。但是,用云杉木屑填充缺口对UW的传播影响可忽略不计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号