RATIONALE AND OBJECTIVES: To compare manganese dipyridoxyl diphosphate (MnDPDP)-enhanced magnetic resonance imaging (MRI) with cine MRI for distinguishing the dysfunctional myocardium from the normal myocardium. MATERIALS AND METHODS: Seventeen cats were prepared for acute myocardial infarction with 90 minutes of occlusion followed by 120 minutes of reperfusion. In vivo inversion-recovery gradient-recalled echo MRI and cine MRI were performed. Two radiologists independently analyzed the MR images and recorded the size of the unenhanced area on the MnDPDP-enhanced MR images as well as that of the dysfunctional area on the cine MR images. Agreement between these abnormal areas was evaluated using Bland-Altman analysis. Interobserver agreement was assessed using Bland-Altman analysis. RESULTS: The sizes of the unenhanced area on the MnDPDP-enhanced MR images and the dysfunctional area on the cine MR images showed good agreement on Bland-Altman analysis (the limits of agreement: observer 1= 1.8% +/- 11.6, observer 2 = 0.1% +/- 9.9). The abnormal segments on both types of MR imaging showed a good interobserver agreement (the limits of agreement: MnDPDP-enhanced MRI = 0.3% +/- 7.6, cine MRI = -1.4% +/- 10.9). CONCLUSION: The size of the dysfunctional area on the cine MR images was well correlated with that of the unenhanced area on the MnDPDP-enhanced MR images.
机译:理由和目的:比较二磷酸锰二吡啶氧基锰(MnDPDP)与电影MRI的区别,以区分功能正常的心肌和正常的心肌。材料与方法:准备了十七只猫进行急性心肌梗塞,阻塞90分钟,然后再灌注120分钟。进行体内倒置-恢复梯度-称为回波MRI和电影MRI。两名放射科医生独立分析了MR图像,并记录了MnDPDP增强MR图像上未增强区域的大小以及电影MR图像上功能障碍区域的大小。使用Bland-Altman分析评估这些异常区域之间的一致性。使用Bland-Altman分析评估了观察者之间的协议。结果:MnDPDP增强的MR图像上未增强区域的大小和电影MR图像上的功能障碍区域的大小在Bland-Altman分析上显示出良好的一致性(一致性的极限:观察者1 = 1.8%+/- 11.6,观察者2 = 0.1%+/- 9.9)。两种类型的MR成像上的异常节段均显示了良好的观察者一致性(一致性的极限:MnDPDP增强MRI = 0.3%+/- 7.6,电影MRI = -1.4%+/- 10.9)。结论:电影MR图像上功能障碍区域的大小与MnDPDP增强MR图像上未增强区域的大小相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号