To evaluate the diagnostic accuracy of computed tomography (CT)-based imaging methods for assessing renal vascular anatomy, imaging studies, including standard axial CT, three-dimensional volume-rendered CT (3DVR-CT), and a 3DVR-CT movie, were performed on 30 patients who underwent laparoscopic donor nephrectomy (10 right side, 20 left side) for predicting the location of the renal arteries and renal, adrenal, gonadal, and lumbar veins. These findings were compared with videos obtained during the operation. Two of 37 renal arteries observed intraoperatively were missed by standard axial CT and 3DVR-CT, whereas all arteries were identified by the 3DVR-CT movie. Two of 36 renal veins were missed by standard axial CT and 3DVR-CT, whereas 1 was missed by the 3DVR-CT movie. In 20 left renal hilar anatomical structures, 20 adrenal, 20 gonadal, and 22 lumbar veins were observed during the operation. Preoperatively, the standard axial CT, 3DVR-CT, and 3DVR-CT movie detected 11, 19, and 20 adrenal veins; 13, 14, and 19 gonadal veins; and 6, 11, and 15 lumbar veins, respectively. Overall, of 135 renal vascular structures, the standard axial CT, 3DVR-CT, and 3DVR-CT movie accurately detected 99 (73.3%), 113 (83.7%), and 126 (93.3%) vessels, respectively, which indicated that the 3DVR-CT movie demonstrated a significantly higher detection rate than other CT-based imaging methods (P < 0.05). The 3DVR-CT movie accurately provides essential information about the renal vascular anatomy before laparoscopic donor nephrectomy.
机译:为了评估基于计算机断层扫描(CT)的成像方法在评估肾血管解剖学方面的诊断准确性,对包括标准轴向CT,三维体积渲染CT(3DVR-CT)和3DVR-CT电影在内的成像研究进行了研究。对30例行腹腔镜供体肾切除术的患者(右侧10例,左侧20例)进行了手术,以预测肾动脉和肾,肾上腺,性腺和腰静脉的位置。将这些发现与手术中获得的视频进行比较。术中观察到的37条肾动脉中有2条被标准轴向CT和3DVR-CT漏诊,而所有动脉均由3DVR-CT影像识别。标准轴向CT和3DVR-CT漏诊了36个肾静脉中的2个,而3DVR-CT电影漏诊了1个。在手术中,在20个左肾门的解剖结构中,观察到20个肾上腺,20个性腺和22个腰静脉。术前,标准的轴向CT,3DVR-CT和3DVR-CT电影可检测到11、19和20个肾上腺静脉。 13、14和19个性腺静脉;和6、11和15个腰静脉。总体而言,在135个肾血管结构中,标准的轴向CT,3DVR-CT和3DVR-CT影片分别准确地检测到了99个(73.3%),113个(83.7%)和126个(93.3%)的血管,表明3DVR-CT电影显示出比其他基于CT的成像方法显着更高的检测率(P <0.05)。 3DVR-CT电影准确地提供了腹腔镜供体肾切除术前有关肾血管解剖结构的基本信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号