A vascular stent as an active component for locally enhanced magnetic resonance imaging: initial in vivo imaging results after catheter-guided placement in rabbits.

机译:血管支架作为局部增强磁共振成像的活性成分:在兔子的导管引导下放置后,初步体内成像结果。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

RATIONALE AND OBJECTIVE: A vascular stent constructed as a high frequency resonator improves the local signal-to-noise ratio at magnetic resonance (MR) imaging. After catheter placement and intravascular expansion, the stent can be used as an inductively coupled coil for MRI. The imaging properties of this balloon-expandable active MRI stent (AMRIS) were evaluated after x-ray fluoroscopy guided placement in the abdominal aorta of five rabbits using MR angiography (MRA) and flow measurements. METHODS: The AMRIS was implanted in the abdominal aorta of five rabbits using a balloon catheter inserted through the common carotid artery. The rabbits were examined by MRA (3D fast low-angle shot) at 1.5 tesla before and after intravenous injection of an iron-oxide-based blood pool contrast medium (dose 50 micro mol Fe/kg) and flow measurements (ECG-triggered phase contrast cine gradient-echo sequence). Signal-to-noise ratios (SNR) were calculated and flow volume curves were generated. The in-stent increase in temperature was measured in vitro using a fiberoptic thermometry system. RESULTS: The SNR was 5.0 +/- 0.6 outside the stent and 23.2 +/- 14.1 within the stent ( < 0.0 5) in plain MRA, 19.5 +/- 5.0 outside and 30.7 +/- 8.2 within the stent ( < 0.05) in contrast enhanced MRA, and 5.8 +/- 1.6 and 13.9 +/- 5.9, respectively ( < 0.05) in the magnitude images of the flow measurements. Flow volume curves within and distal to the stent were comparable. CONCLUSIONS: The expandable active MRI stent produces local signal enhancement in MRA and MR flow measurements after catheter placement and thus may improve assessment of the stented vessel segment by MR imaging.
机译:理由和目的:构造为高频谐振器的血管支架可改善磁共振(MR)成像时的局部信噪比。在导管放置和血管内扩张后,支架可用作MRI的感应耦合线圈。在使用MR血管造影术(MRA)和血流测量仪对X射线透视引导下将五只兔子的腹主动脉内放置后,评估了该球囊可扩张式活动MRI支架(AMRIS)的成像特性。方法:通过插入穿过颈总动脉的球囊导管,将AMRIS植入五只兔子的腹主动脉中。在静脉内注射基于铁氧化物的血池造影剂(剂量为50 micro mol Fe / kg)之前和之后,在1.5特斯拉下通过MRA(3D快速低角度拍摄)检查兔子,并进行流量测量(ECG触发相)对比电影梯度回波序列)。计算信噪比(SNR)并生成流量曲线。使用光纤测温系统在体外测量支架内温度的升高。结果:在普通MRA中,支架外的SNR为5.0 +/- 0.6,在支架内的SNR为23.2 +/- 14.1(<0.0 5),在支架内的SNR为19.5 +/- 5.0和30.7 +/- 8.2(<0.05)相反,在流量测量的幅值图像中,MRA增强了,分别为5.8 +/- 1.6和13.9 +/- 5.9(<0.05)。支架内和支架外的流量曲线相当。结论:可扩展的主动MRI支架在放置导管后在MRA和MR流量测量中产生局部信号增强,因此可以改善通过MR成像对支架血管段的评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号