This retrospective descriptive study was performed to assess the practice of using the distal urethral electrical conductance (DUEC) test to objectively demonstrate urinary incontinence in symptomatic women with a negative cough stress test on examination. One hundred women had stable bladders on cystometry (CMG). Genuine stress incontinence (GSI) was diagnosed during CMG in 45 (45%). DUEC performed prior to cystometry had revealed stress incontinence in an additional 13 with negative CMG, thereby improving the diagnosis of GSI by 13%. The test detected urge incontinence in one (1%). The DUEC test improves the detection of stress incontinence. However, it should not be considered as an alternative to cystometry, but as an additional test when stress incontinence cannot be demonstrated clinically.
机译:进行这项回顾性描述性研究,以评估使用远端尿道电导(DUEC)测试客观显示症状女性的尿失禁情况,并在检查时使用咳嗽压力测试为阴性。一百名妇女的膀胱测压(CMG)膀胱稳定。在CMG期间诊断为真正的压力性尿失禁(GSI)的患者为45(45%)。膀胱测压术前进行的DUEC检查显示,另外13例CMG阴性,压力性尿失禁,从而将GSI的诊断提高了13%。该测试检测到急迫性尿失禁的比例为1(1%)。 DUEC测试可改善压力性尿失禁的检测。但是,不应将其视为膀胱测压术的替代方法,而应作为无法在临床上证实为压力性尿失禁的其他测试。