...
首页> 外文期刊>Investigative ophthalmology & visual science >Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears.
【24h】

Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears.

机译:滴注人工泪液后,重复测量眼表动态泪液分布。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

PURPOSE: To determine the repeatability of real-time optical coherence tomography (OCT) measurements of tear film thickness (TFT) and variables of tear film menisci. METHODS: Forty eyes were imaged with a custom-built, real-time OCT to obtain heights, curvatures, and cross-sectional areas of upper and lower tear menisci simultaneously. The central TFT was indirectly determined as the difference between the combined thickness of the central cornea and tear film and the true corneal thickness obtained after instillation of artificial tears. Dynamic tear distribution was determined by OCT imaging immediately and 5, 20, 40, and 60 minutes after tear instillation. Measurements taken after two blinks of one eye at each visit were repeated on the next day. Measurements from the companion eye were made on separate days. RESULTS: There were no significant differences between the two measurements of each variable made on consecutive days. At baseline, upper tear meniscus variables were strongly correlated with the comparable lower meniscus variables. However, there were no significant correlations between TFT and any tear meniscus variable. Immediately after instillation of artificial tears, all measured variables increased significantly. TFT, upper and lower menisci heights, and upper meniscus area remained elevated for at least 5 minutes. In addition there were significant correlations between TFT and the lower tear meniscus height and area. CONCLUSIONS: The custom-built OCT showed good repeatability and holds promise in measuring the dynamic distribution of artificial tears on the ocular surface.
机译:目的:确定泪膜厚度(TFT)和泪膜半月板变量的实时光学相干层析成像(OCT)测量的可重复性。方法:用定制的实时OCT对四十只眼睛进行成像,以同时获得上下泪液弯液面的高度,曲率和横截面积。中央TFT间接地确定为中央角膜和泪膜的总厚度与滴入人工泪液后获得的真实角膜厚度之间的差。眼泪滴注后立即,以及在5、20、40和60分钟通过OCT成像确定动态眼泪分布。隔天重复两次在每次拜访中一只眼睛眨了眨眼后所进行的测量。从伴侣的眼睛进行的测量是在不同的日子进行的。结果:在连续几天对每个变量进行的两次测量之间没有显着差异。在基线,上半月板撕裂变量与可比的下半月板变量密切相关。但是,TFT与任何撕裂弯液面变量之间没有显着相关性。滴入人工泪液后,所有测量变量立即显着增加。 TFT,上半月板和下半月板的高度以及上半月板区域至少持续升高了5分钟。另外,TFT与较低的撕裂弯液面高度和面积之间存在显着的相关性。结论:定制的OCT显示出良好的可重复性,并有望在眼表上测量人工泪液的动态分布。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号