...
首页> 外文期刊>Investigative ophthalmology & visual science >Semiquantitative optic nerve grading scheme for determining axonal loss in experimental optic neuropathy.
【24h】

Semiquantitative optic nerve grading scheme for determining axonal loss in experimental optic neuropathy.

机译:半定量视神经分级方案,用于确定实验性视神经病变的轴突丢失。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To describe and evaluate a semiquantitative optic nerve grading scheme for assessing axonal loss in endothelin (ET)-1-induced chronic optic neuropathy. METHODS: Optic nerve cross-sections from both eyes of 39 Brown Norway rats unilaterally treated with various concentrations of ET-1 or physiological saline solution via a surgically implanted osmotic minipump were processed for light and transmission electron microscopy (TEM). The optic nerve damage grade, between 0 (no damage) and 10 (total damage), was based on the number of zones of approximately equal damage and the mean percentage of damage within each zone. Grading was performed under light microscopy by three observers and compared with axonal survival determined with TEM using two quantification methods: the sampling method, in which approximately 10% of the section was counted, and the full-count method, in which the whole section was counted (n = 12). Axonal survival was expressed as a ratio of axon counts in the experimental to control eye. Before these comparisons, the inter- and intraobserver agreement rates were determined in another group of 85 and 12 ET-1-treated animals, respectively. RESULTS: The interobserver kappa was 0.66 (95% confidence interval [CI]: 0.58-0.74) for all eyes and 0.55 (95% CI: 0.43-0.67) for the experimental eyes only. The intraobserver kappa was 0.80, 0.81, and 0.80 for all 24 eyes and 0.60, 0.64, and 0.71 for experimental eyes only. The correlation between damage grade in the experimental eye and axonal survival using the TEM sampling method (Spearman's rho = -0.677 for all animals and -0.827 for the subset of animals with full counts only) was lower than that with the full-count method (Spearman's rho = -0.926). When axonal survival was less than 0.7, the sampling method always underestimated the extent of damage. CONCLUSIONS: The grading scheme had good inter- and intraobserver agreement, and high correlation with the TEM methods. It is a practical and time-saving method, requiring less than 1 minute per nerve and is an alternative to sampling methods that can yield significant errors.
机译:目的:描述和评估一种半定量视神经分级方案,以评估内皮素(ET)-1引起的慢性视神经病变的轴突丧失。方法:通过手术植入的渗透性微型泵对39只布朗挪威大鼠单侧用各种浓度的ET-1或生理盐水溶液处理的两只眼睛的视神经横截面进行光镜和透射电子显微镜(TEM)处理。视神经损伤等级介于0(无损伤)和10(总损伤)之间,是基于损伤程度大致相等的区域数量以及每个区域内损伤的平均百分比。由三名观察员在光学显微镜下进行分级,并与通过两种定量方法通过TEM测定的轴突存活率进行比较:抽样方法,其中对大约10%的切片进行计数;全计数法,其中对整个切片进行计数。计数(n = 12)。轴突存活率表示为实验眼与对照眼中轴突计数的比率。在进行这些比较之前,分别确定了另一组分别由85只和12只ET-1处理过的动物的观察者之间和观察者内部的同意率。结果:所有实验者的观察者间kappa值为0.66(95%置信区间[CI]:0.58-0.74),而实验性眼的观察者间kappa值为0.55(95%CI:0.43-0.67)。所有24只眼睛的观察者内部kappa分别为0.80、0.81和0.80,仅实验性眼睛的内部观察者kappa分别为0.60、0.64和0.71。使用TEM采样方法(所有动物的Spearman rho = -0.677和仅具有完整计数的动物子集-0.827),实验眼的损伤等级与轴突存活之间的相关性低于完整计数方法( Spearman的rho = -0.926)。当轴突存活率小于0.7时,采样方法总是低估了损伤的程度。结论:该分级方案在观察者之间和观察者内部具有良好的一致性,并且与TEM方法具有高度相关性。这是一种实用且省时的方法,每条神经不到1分钟,并且是可能产生重大错误的采样方法的替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号