PURPOSE: To examine the deposition of tear phospholipids and cholesterol onto worn contact lenses and the effect of lens material and lens care solution. METHODS: Lipids were extracted from tears and worn contact lenses using 2:1 chloroform:methanol and the extract washed with aqueous ammonium acetate, before analysis by electrospray ionization tandem mass spectrometry (ESI-MS/MS). RESULTS: Twenty-three molecular lipids from the sphingomyelin (SM) and phosphatidylcholine (PC) classes were detected in tears, with total concentrations of each class determined to be 5 +/- 1 pmol/microL ( approximately 3.8 microg/mL) and 6 +/- 1 pmol/microL ( approximately 4.6 microg/mL), respectively. The profile of individual phospholipids in both of these classes was shown to be similar in contact lens deposits. Deposition of representative polar and nonpolar lipids were shown to be significantly higher on senofilcon A contact lenses, with approximately 59 ng/lens SM, 195 ng/lens PC, and 9.9 microg/lens cholesterol detected, whereas balafilcon A lens extracts contained approximately 19 ng/lens SM, 19 ng/lens PC, and 3.9 microg/lens cholesterol. Extracts from lenses disinfected and cleaned with two lens care solutions showed no significant differences in total PC and SM concentrations; however, a greater proportion of PC than SM was observed, compared with that in tears. CONCLUSIONS: Phospholipid deposits extracted from worn contact lenses show a molecular profile similar to that in tears. The concentration of representative polar and nonpolar lipids deposited onto contact lenses is significantly affected by lens composition. There is a differential efficacy in the removal of PC and SM with lens care solutions.
机译:目的:检查眼泪磷脂和胆固醇在磨损的隐形眼镜上的沉积以及镜片材料和镜片护理液的作用。方法:使用电喷雾电离串联质谱(ESI-MS / MS)分析之前,使用2:1氯仿:甲醇从眼泪和磨损的隐形眼镜中提取脂质,并用乙酸铵水溶液洗涤提取物。结果:在眼泪中检测到鞘磷脂(SM)和磷脂酰胆碱(PC)类的23种分子脂质,每种类的总浓度确定为5 +/- 1 pmol / microL(约3.8 microg / mL)和6分别为+/- 1 pmol / microL(约4.6 microg / mL)。这两种类别的单个磷脂的分布在隐形眼镜沉积物中均显示相似。 senofilcon A隐形眼镜的代表性极性脂质和非极性脂质的沉积量显着更高,检测出约59 ng /透镜的SM,195 ng /透镜的PC和9.9 microg /透镜的胆固醇,而Balafilcon A透镜提取物的含量约为19 ng /透镜/ lens SM,19 ng / lens PC和3.9 microg / lens胆固醇。用两种镜片护理液消毒和清洁过的镜片提取物在总PC和SM浓度上没有显着差异。然而,与眼泪相比,PC中PC的比例要比SM高。结论:从磨损的隐形眼镜中提取的磷脂沉积物具有类似于眼泪的分子轮廓。沉积在隐形眼镜上的代表性极性和非极性脂质的浓度受镜片组成的影响很大。用镜片护理液去除PC和SM的功效不同。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号