Exergy losses in elements of a steam-water injector have been determined. Exemplary calculations based on the experimental data showed that the highest irreversible losses take place in a two-phase flow in the mixing chamber and in the shock wave region. The exergy efficiency for the injector, defined as the outlet to inlet exergy ratio, has been found to lie in the range of 28-36%.