A novel electrochemical sensor for the selective determination of mebeverine hydrochloride (MEB) in drug substance, products, and human plasma was introduced. The prepared nanoparticle sensor was based on a carbon paste electrode chemically modified with silica and gold nanoparticles. The surface morphology of the modified electrode was characterized by scanning electron microscope. Several parameters such as pH, scan rate, and accumulation time were optimized in order to determine the best conditions for analysis. A good linear response was obtained in the range of 4.0 x 10(-8)-1 x 10(-5) mol L-1 with detection limit of 1.5 x 10(-9) mol L-1. The obtained results are in good agreement with those obtained by official method. The method was applied for determination of mebeverine hydrochloride in different pharmaceutical dosage forms containing MEB alone or in mixtures with sulpiride or chlordiazepoxide as well as in human plasma. The developed method was simple, rapid, economic, and challenging to green chemistry.
机译:介绍了一种新型电化学传感器,用于选择性测定原料药,产品和人体血浆中的盐酸美贝维林(MEB)。所制备的纳米粒子传感器基于经二氧化硅和金纳米粒子化学修饰的碳糊电极。用扫描电子显微镜对修饰电极的表面形貌进行表征。为了确定最佳分析条件,对诸如pH,扫描速率和累积时间等几个参数进行了优化。在4.0 x 10(-8)-1 x 10(-5)mol L-1的范围内获得了良好的线性响应,检测极限为1.5 x 10(-9)mol L-1。所得结果与通过官方方法获得的结果吻合良好。该方法适用于测定单独含有MEB或与舒必利或氯二氮卓混合使用的不同药物剂型中盐酸美贝维林的浓度,以及该方法在人体血浆中的含量。所开发的方法简单,快速,经济并且对绿​​色化学具有挑战性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号