摘要

We reviewed a series of consecutive total hip replacements with cemented femoral components. Modern cementing techniques were followed in all cases, but two different medullary plugs were used-one was polyethylene and the other bioabsorbable gelatin. Cement mantle quality and plug migration were assessed by three different observers (X, Y, and Z); their findings did not agree. This was particularly evident when the cement mantles were assessed. There was a better cement mantle grading and less distal migration with polyethylene plugs, although there was no significant statistical difference between the two groups.
机译:我们回顾了一系列连续的全髋关节置换术,其中包括股骨骨水泥成分。在所有情况下均采用现代固井技术,但使用了两种不同的髓栓-一种是聚乙烯,另一种是可生物吸收的明胶。由三个不同的观察者(X,Y和Z)评估了水泥地幔质量和塞子迁移。他们的发现不同意。当评估水泥地幔时,这一点尤其明显。尽管两组之间没有显着的统计学差异,但聚乙烯栓塞的水泥衬层分级更好,远端迁移较少。