Purpose: In total hip arthroplasty fixation of revision stems can be demanding due to femoral bone loss. Strut grafts are often used for bone augmentation and stabilization of the newly inserted prosthesis. The aim of this study was to assess the effect of strut grafts on primary stability under various stem fixation conditions. Methods: Two different revision stems (cylindrical and conical shape) were implanted into synthetic femora. Following a semicircular transfemoral osteotomy, three deficient femoral bearings were simulated (bony lid reattached with cable wires; weakened lid reattachedwith cable wires; strut grafts placed to the weakened lid with cable wires). Relative micro-movements were measured between prostheses and bones due to an axial moment applied to the stems. Results: Relative movements correlated to the stem shape. The cylindrical stem showed higher movements increasing significantly with a weakened bony lid and portrayed a slight decrease of movements with strut graft application. No unequivocal influence of the weakened lid could be detected for the conical implant. Strut graft application did not show an additional stabilizing effect. Conclusions: The primary stability of the cylindrical fixation concept decreases with impaired fixation conditions of the femur. A clear restabilizing effect with strut grafts could not be proven. A decrease of primary stability due to the impaired bone could not be observed for the conical stem shape. Additionally, strut grafts do not enhance fixation for this stem shape. We conclude that surgeons should not rely on a stabilizing effect of strut grafts in revision hip surgery.
机译:目的:在全髋关节置换术中,由于股骨丢失,可能需要对翻修茎进行固定。支杆移植物通常用于新插入的假体的骨增强和稳定。这项研究的目的是评估在各种茎固定条件下支杆移植对初级稳定性的影响。方法:将两个不同的翻修茎(圆柱形和圆锥形)植入到人工股骨中。在半圆形经股骨截骨术之后,模拟了三个缺陷的股骨轴承(将骨盖重新装上电缆线;将弱盖重新装上电缆线;将支撑杆移植物通过缆线放置到已变弱的盖上)。由于施加在杆上的轴向力矩,在假体和骨骼之间测量了相对的微动。结果:相对运动与茎的形状相关。圆柱状茎显示出较高的运动,但骨盖变弱,运动显着增加,而应用支撑物移植后,运动略有减少。对于锥形植入物,没有检测到减弱的盖子的明确影响。支撑移植物未显示出其他稳定作用。结论:圆柱形固定概念的主要稳定性随着股骨固定条件的降低而降低。支撑杆移植物没有明显的稳定作用。对于圆锥形茎的形状,未观察到由于骨骼受损而引起的初级稳定性下降。另外,支撑移植物不能增强该茎的形状。我们得出的结论是,外科医生在翻修髋关节手术中不应依赖支杆移植物的稳定作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号