The Proportion of Residences in European Countries with Ventilation Rates below the Regulation Based Limit Value

机译:通风率低于法规限值的欧洲国家中的住宅比例

获取原文
获取原文并翻译 | 示例
           

摘要

The rate of ventilation in buildings is regulated in most European countries to provide a sufficient exchange of clean air to maintain and ensure the health and comfort of building occupants. Information on the actual level of ventilation rates is needed to estimate the consequences of reduced ventilation on the potential increasing risk of health problems. Unfortunately only limited population based data are available on the measured ventilation rates of residences in European countries. To fill this data gap a model was developed that combines information from existing measurements, national legislation and building codes to estimate the probability distributions of ventilation rates in the residences of 26 European countries. These distributions were analysed against national building statistics to produce information on the number of residences which do not meet ventilation requirements as defined by the relevant national building codes.Earlier results suggest that the mean ± SD air change rate per hour (ac/h) in residences varies from 0.6±0.4 in northern Europe to 1.1 ± 0.8 in southern Europe, and the population weighted mean of the 26 European countries is 0.8 ± 0.5. Further analysis of the distributions indicated that, on average, 32% of the residences in the 17 European countries that have some regulations defining minimum ventilation rates have mean air change rates below the defined limits. This means that around 53 million residences in total with an estimated number of people living in these residences of approximately 126 million are under ventilated. At country level the percentage of residences having mean ventilation rate below the national limit varies from 7% in Bulgaria to 46% in the Netherlands. In addition, the proportion of residences with mean ventilation rates below three other limit values: 1) 8 L/s per person, 2) 0.5 ac/h based on the EN15251 standard, and 3) a limit value based on the ASHRAE 62.1 standard were estimated.
机译:大多数欧洲国家/地区都对建筑物的通风率进行了规定,以提供足够的清洁空气交换,以维持并确保建筑物居住者的健康和舒适。需要有关通风率的实际水平的信息,以估计通风不足对健康问题潜在增加风险的后果。不幸的是,只有有限的基于人口的数据可用于测量欧洲国家住宅的通风率。为了填补这一数据空白,开发了一个模型,该模型结合了来自现有测量,国家法规和建筑法规的信息,以估算26个欧洲国家住宅中通风率的概率分布。根据国家建筑统计数据对这些分布进行了分析,以得出不符合相关国家建筑法规定义的通风要求的住宅数量的信息。早期的结果表明,每小时平均±SD空气变化率(ac / h)居住地从北欧的0.6±0.4到南欧的1.1±0.8,26个欧洲国家的人口加权平均数为0.8±0.5。对分布的进一步分析表明,在17个欧洲国家中,平均有32%的住宅有一些规定最低通风率的法规,其平均换气率低于规定的限值。这意味着总共约有5300万个住宅通风,其中估计有约1.26亿人居住在通风之中。在国家一级,平均通风率低于国家规定的住宅百分比在保加利亚为7%,在荷兰为46%。此外,平均通风率低于其他三个极限值的住宅比例:1)每人8 L / s; 2)根据EN15251标准的0.5 ac / h;以及3)根据ASHRAE 62.1标准的极限值被估计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号