The main purpose of this paper is to evaluate the main fluid mechanics parameters in the exit region of three different terminal systems commonly used for controlled environments such as clean rooms or operating theatres. Three different types of diffuser were tested i.e. a diffuser grid, a square ceiling diffuser and a swirling radial discharge diffuser. The paper presents results obtained experimentally which were carried out in order to study the flow characteristics of isothermal jets issuing from such devices. The study has been performed for four different air flow rates for each type of terminal tested. To characterise the flow with confidence and obtain high spatial resolution, a Particle Image Velocimetry technique and a Laser Doppler Velocimetry technique were used. For each case investigated, the results were plotted as velocity profile, velocity magnitude, turbulence intensity and vorticity. The study displays the particular behaviour of the flow generated by each terminal. Vorticity regions and turbulence spots were also detected and carefully localised for the investigated configurations.
机译:本文的主要目的是评估通常用于受控环境(如无尘室或手术室)的三种不同终端系统出口区域的主要流体力学参数。测试了三种不同类型的扩散器,即扩散器栅格,方形天花板扩散器和涡旋径向排放扩散器。本文介绍了通过实验获得的结果,以研究此类设备发出的等温射流的流动特性。对于每种类型的终端,已经针对四种不同的空气流速进行了研究。为了可靠地表征流并获得高空间分辨率,使用了粒子图像测速技术和激光多普勒测速技术。对于每个调查的案例,将结果绘制为速度分布图,速度大小,湍流强度和涡度。该研究显示了每个终端生成的流的特定行为。涡流区域和湍流点也被检测到并仔细定位以用于研究配置。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号