首页> 外文期刊>International Journal of Thermal Sciences >Transient evaluation of a city bus air conditioning system with R-445A as drop-in - From the molecules to the system
【24h】

Transient evaluation of a city bus air conditioning system with R-445A as drop-in - From the molecules to the system

机译:带有R-445A的城市公交车空调系统的瞬态评估-从分子到系统

获取原文
获取原文并翻译 | 示例
           

摘要

A method for calculating the thermophysical properties of the blend R-445A is presented. The data were then employed in a transient simulation of an R-134a air conditioning system in a city bus operating with R-445A to evaluate the blend under transient boundary conditions. The cumulated COP of the reference R-134a system, derived from the cumulated cooling capacity divided by the cumulated compressor power, is ca. 3.9. Using R-445A as drop-in, the cumulated COP is ca. 8% lower, and also the maximum cooling capacity is reduced, whereas the high pressure and the compressor outlet temperature increase. Furthermore there is a higher risk of ice formation at the evaporator. Selective leakage of R-445A may cause a COP increase and a maximum cooling capacity decrease over the operation time. (C) 2015 Elsevier Masson SAS. All rights reserved.
机译:提出了一种计算共混物R-445A的热物理性质的方法。然后将数据用于运行R-445A的城市公交车中R-134a空调系统的瞬态仿真,以评估瞬态边界条件下的混合气。参考R-134a系统的累积COP约为累积制冷量除以压缩机的累积功率。 3.9。使用R-445A作为插件,累积的COP约为。降低8%,最大冷却能力也降低,而高压和压缩机出口温度升高。此外,在蒸发器上形成冰的风险更高。 R-445A的选择性泄漏可能会导致COP升高,并且在整个运行时间内最大冷却能力降低。 (C)2015 Elsevier Masson SAS。版权所有。