The results obtained in the characterization of a low-temperature comparator and its performance in relation to the calibration of metal and borosilicate sheathed standard platinum resistance thermometers (SPRTs) calibrated at the International Temperature Scale of 1990 (ITS-90) fixed points, are presented and discussed. The principal influence quantities are addressed and the estimation of measurement uncertainty supporting the calibration and measurement capability (CMC) accredited by Entidad Nacional de Acreditacion (ENAC), the Spanish Accreditation Body, are presented and discussed.
机译:介绍了低温比较器的表征及其在校准1990年国际温度标度(ITS-90)的金属和硼硅酸盐护套标准铂电阻温度计(SPRT)方面的性能。和讨论。解决了主要影响量,并介绍并讨论了由西班牙认证机构(ENAC)认可的支持校准和测量能力(CMC)的测量不确定度估计。