Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy.

机译:在门控放疗中,使用呼吸传感器测量的呼吸波形与3D肿瘤运动之间的相关性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: The purpose of this study is to investigate the correlation between the respiratory waveform measured using a respiratory sensor and three-dimensional (3D) tumor motion. METHODS AND MATERIALS: A laser displacement sensor (LDS: KEYENCE LB-300) that measures distance using infrared light was used as the respiratory sensor. This was placed such that the focus was in an area around the patient's navel. When the distance from the LDS to the body surface changes as the patient breathes, the displacement is detected as a respiratory waveform. To obtain the 3D tumor motion, a biplane digital radiography unit was used. For the tumor in the lung, liver, and esophagus of 26 patients, the waveform was compared with the 3D tumor motion. The relationship between the respiratory waveform and the 3D tumor motion was analyzed by means of the Fourier transform and a cross-correlation function. RESULTS: The respiratory waveform cycle agreed with that of the cranial-caudal and dorsal-ventral tumor motion. A phaseshift observed between the respiratory waveform and the 3D tumor motion was principally in the range 0.0 to 0.3 s, regardless of the organ being measured, which means that the respiratory waveform does not always express the 3D tumor motion with fidelity. For this reason, the standard deviation of the tumor position in the expiration phase, as indicated by the respiratory waveform, was derived, which should be helpful in suggesting the internal margin required in the case of respiratory gated radiotherapy. CONCLUSION: Although obtained from only a few breathing cycles for each patient, the correlation between the respiratory waveform and the 3D tumor motion was evident in this study. If this relationship is analyzed carefully and an internal margin is applied, the accuracy and convenience of respiratory gated radiotherapy could be improved by use of the respiratory sensor.Thus, it is expected that this procedure will come into wider use.
机译:目的:本研究的目的是调查使用呼吸传感器测量的呼吸波形与三维(3D)肿瘤运动之间的相关性。方法和材料:使用红外光测量距离的激光位移传感器(LDS:KEYENCE LB-300)被用作呼吸传感器。放置时应使焦点位于患者肚脐周围的区域。当LDS到身体表面的距离随着患者的呼吸而改变时,该位移被检测为呼吸波形。为了获得3D肿瘤运动,使用了双平面数字X射线照相装置。对于26例患者的肺,肝和食道肿瘤,将波形与3D肿瘤运动进行了比较。通过傅立叶变换和互相关函数分析了呼吸波形与3D肿瘤运动之间的关系。结果:呼吸波形周期与颅-尾和背-腹肿瘤运动的周期一致。不管所测量的器官如何,在呼吸波形和3D肿瘤运动之间观察到的相移原则上都在0.0到0.3 s的范围内,这意味着呼吸波形并不总是准确地表达3D肿瘤运动。因此,如呼吸波形所示,得出了呼气期肿瘤位置的标准偏差,这有助于建议进行门控放疗的内部余量。结论:尽管从每位患者仅通过几个呼吸周期即可获得,但在本研究中呼吸波形与3D肿瘤运动之间的相关性很明显。如果仔细分析这种关系并应用内部余量,则可以通过使用呼吸传感器来提高呼吸门控放疗的准确性和便利性,因此,预计该程序将被广泛使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号