...
首页> 外文期刊>International Journal of Radiation Oncology, Biology, Physics >The influence of changes in tumor hypoxia on dose-painting treatment plans based on 18F-FMISO positron emission tomography.
【24h】

The influence of changes in tumor hypoxia on dose-painting treatment plans based on 18F-FMISO positron emission tomography.

机译:肿瘤缺氧的变化对基于18F-FMISO正电子发射断层显像的剂量治疗方案的影响。

获取原文
获取原文并翻译 | 示例

摘要

PURPOSE: To evaluate how changes in tumor hypoxia, according to serial fluorine-18-labeled fluoro-misonidazole (18F-FMISO) positron emission tomography (PET) imaging, affect the efficacy of intensity-modulated radiotherapy (IMRT) dose painting. METHODS AND MATERIALS: Seven patients with head and neck cancers were imaged twice with FMISO PET, separated by 3 days, before radiotherapy. Intensity-modulated radiotherapy plans were designed, on the basis of the first FMISO scan, to deliver a boost dose of 14 Gy to the hypoxic volume, in addition to the 70-Gy prescription dose. The same plans were then applied to hypoxic volumes from the second FMISO scan, and the efficacy of dose painting evaluated by assessing coverage of the hypoxic volumes using Dmax, Dmin, Dmean, D95, and equivalent uniform dose (EUD). RESULTS: Similar hypoxic volumes were observed in the serial scans for 3 patients but dissimilar ones for the other 4. There was reduced coverage of hypoxic volumes of the second FMISO scan relative to that of the first scan (e.g., the average EUD decreased from 87 Gy to 80 Gy). The decrease was dependent on the similarity of the hypoxic volumes of the two scans (e.g., the average EUD decrease was approximately 4 Gy for patients with similar hypoxic volumes and approximately 12 Gy for patients with dissimilar ones). CONCLUSIONS: The changes in spatial distribution of tumor hypoxia, as detected in serial FMISO PET imaging, compromised the coverage of hypoxic tumor volumes achievable by dose-painting IMRT. However, dose painting always increased the EUD of the hypoxic volumes.
机译:目的:根据系列氟18标记的氟代咪唑(18F-FMISO)正电子发射断层扫描(PET)成像,评估肿瘤缺氧的变化如何影响强度调节放射治疗(IMRT)剂量的效果。方法和材料:FMISO PET对7例头颈癌患者进行了两次放射成像,相隔3天,然后进行放射治疗。在第一次FMISO扫描的基础上,设计了强度调节放疗计划,除了70 Gy处方剂量外,还向低氧量提供了14 Gy的增强剂量。然后将相同的计划应用于来自第二次FMISO扫描的低氧量,并通过使用Dmax,Dmin,Dmean,D95和等效均等剂量(EUD)评估低氧量的覆盖率来评估剂量涂装的效果。结果:3例患者在连续扫描中观察到相似的低氧容量,而其他4例患者则观察到不同。相对于第一次扫描,第二次FMISO扫描的低氧容量覆盖率降低了(例如,平均EUD从87降低了Gy至80 Gy)。降低取决于两次扫描的低氧量的相似性(例如,低氧量相似的患者的平均EUD降低约4 Gy,而异氧量相似的患者的平均EUD降低约12 Gy)。结论:在连续FMISO PET成像中检测到的肿瘤缺氧的空间分布变化,损害了通过剂量彩绘IMRT可获得的缺氧肿瘤体积的覆盖范围。但是,剂量涂装始终会增加缺氧量的EUD。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号