...
首页> 外文期刊>International Journal of Radiation Oncology, Biology, Physics >Predictors of long-term toxicity using three-dimensional conformal external beam radiotherapy to deliver accelerated partial breast irradiation.
【24h】

Predictors of long-term toxicity using three-dimensional conformal external beam radiotherapy to deliver accelerated partial breast irradiation.

机译:使用三维共形外部束放射疗法来提供加速的局部乳房照射的长期毒性预测指标。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: We analyzed variables associated with long-term toxicity using three-dimensional conformal external beam radiation therapy (3D-CRT) to deliver accelerated partial breast irradiation. METHODS AND MATERIALS: One hundred patients treated with 3D-CRT accelerated partial breast irradiation were evaluated using Common Terminology Criteria for Adverse Events version 4.0 scale. Cosmesis was scored using Harvard criteria. Multiple dosimetric and volumetric parameters were analyzed for their association with worst and last (W/L) toxicity outcomes. RESULTS: Sixty-two patients had a minimum of 36 months of toxicity follow-up (median follow-up, 4.8 years). The W/L incidence of poor-fair cosmesis, any telangiectasia, and grade >/=2 induration, volume reduction, and pain were 16.4%/11.5%, 24.2%/14.5%, 16.1%/9.7%, 17.7%/12.9%, and 11.3%/3.2%, respectively. Only the incidence of any telangiectasia was found to be predicted by any dosimetric parameter, with the absolute breast volume receiving 5% to 50% of the prescription dose (192.5 cGy-1925 cGy) being significant. No associations with maximum dose, volumes of lumpectomy cavity, breast, modified planning target volume, and PTV, dose homogeneity index, number of fields, and photon energy used were identified with any of the aforementioned toxicities. Non-upper outer quadrant location was associated with grade >/=2 volume reduction (p = 0.02 W/p = 0.04 L). A small cavity-to-skin distance was associated with a grade >/=2 induration (p = 0.03 W/p = 0.01 L), a borderline significant association with grade >/=2 volume reduction (p = 0.06 W/p = 0.06 L) and poor-fair cosmesis (p = 0.08 W/p = 0.09 L), with threshold distances ranging from 5 to 8 mm. CONCLUSIONS: No dose--volume relationships associated with long-term toxicity were identified in this large patient cohort with extended follow-up. Cosmetic results were good-to-excellent in 88% of patients at 5 years.
机译:目的:我们使用三维共形外束放射疗法(3D-CRT)分析了与长期毒性相关的变量,以提供加速的局部乳房照射。方法和材料:使用《 4.0版不良事件通用术语标准》评估了接受3D-CRT加速部分乳房照射治疗的100名患者。使用哈佛标准对美容化妆品进行了评分。分析了多个剂量和体积参数与最差和最后(W / L)毒性结果的关系。结果:62名患者接受了至少36个月的毒性随访(中位随访4.8年)。美容不良,任何毛细血管扩张和> / = 2级硬结,体积减少和疼痛的W / L发生率分别为16.4%/ 11.5%,24.2%/ 14.5%,16.1%/ 9.7%,17.7%/ 12.9 %和11.3%/ 3.2%。通过任何剂量学参数只能预测到任何毛细血管扩张的发生率,绝对乳腺体积占处方剂量(192.5 cGy-1925 cGy)的5%至50%是显着的。没有发现与最大剂量,肿块切除术腔的体积,乳房,修改后的计划目标体积和PTV,剂量均一性指数,视野数和所用光子能量之间的相关性与上述任何毒性。非上外部象限位置与等级> / = 2的体积减小有关(p = 0.02 W / p = 0.04 L)。较小的腔至皮肤距离与> / = 2硬度(p = 0.03 W / p = 0.01 L)相关,与> / = 2的体积减小(p = 0.06 W / p = 0.06 L)和较差的美容效果(p = 0.08 W / p = 0.09 L),阈值距离范围为5至8 mm。结论:在这个大型患者队列中,没有随访发现与长期毒性相关的剂量-体积关系。 5年时88%的患者的美容效果良好。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号