首页> 外文期刊>International Journal of Refrigeration >A study of accurate latent heat measurement for a PCM with a low melting temperature using T-history method
【24h】

A study of accurate latent heat measurement for a PCM with a low melting temperature using T-history method

机译:使用T历史法精确测量低熔点PCM的潜热的研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

When the latent heat of a phase change material (PCM) with a lower melting point than ambient temperature was assessed according to the standard T-history method using a vertically oriented test tube, a temperature gradient occurred in the longitudinal direction of the tube due to natural convection. This led to a decrease in the accuracy of the latent heat of fusion measurement. In this study, the accuracy of the measurement with the original T-history method was improved without decreasing the test's simplicity and convenience by setting the test tube horizontally. The heat transfer to the vapor-layer of the tube under volume change during melting was assumed to be negligible and the results were calculated using the two inflection points of temperature as the start and end of latent heat period. Under these assumptions, the results agree closely with other reference data. And, the new method proposed in this study showed a remarkable reduction in data scattering.
机译:当使用垂直取向的试管根据标准的T历史方法评估熔点低于环境温度的相变材料(PCM)的潜热时,在试管的纵向上会出现温度梯度,这是由于自然对流。这导致熔融测量的潜热的精度降低。在这项研究中,通过水平放置试管,在不降低测试简便性和便利性的情况下,提高了使用原始T历史方法进行测量的准确性。假设在熔化过程中在体积变化下传给管子蒸气层的热量可以忽略不计,并且使用温度的两个拐点作为潜热周期的开始和结束来计算结果。在这些假设下,结果与其他参考数据非常吻合。并且,这项研究中提出的新方法显示出数据散射的显着减少。