When the plate thickness is less than 10 mm, testing with standard sized Charpy-V notch specimens is impossible. In such cases the testing must be based on sub-sized specimens. Sometimes, standard size specimens are impractical also for thicker sections. The use of sub-sized specimens requires extrapolation of the result from the sub-sized specimen to correspond to the result from a standard sized specimen. In this work, literature data combined with newly generated data were collected and examined in order to find the correct normalisation procedure for sub-sized specimen, upper shelf impact energy data. The resulting normalisation procedure, combined with a new Charpy-V-J-R curve correlation, was shown to produce realistic estimates of the materials upper shelf fracture toughness. In the case of materials showing pronounced splitting in the Charpy-V test, the estimates may be over-conservative.
机译:当板厚度小于10 mm时,无法使用标准尺寸的Charpy-V缺口样品进行测试。在这种情况下,测试必须基于小尺寸的样本。有时,标准尺寸的标本对于较厚的截面也不可行。使用小尺寸样本需要将小尺寸样本的结果外推,以与标准大小样本的结果相对应。在这项工作中,文献数据与新生成的数据相结合,并进行了收集和检查,以找到正确的归一化程序以用于小尺寸试样,上层架冲击能量数据。结果表明,归一化程序与新的Charpy-V-J-R曲线相关性相结合,可以对材料的上部搁板断裂韧性进行实际估算。如果材料在Charpy-V测试中显示出明显的分裂,则估计值可能过于保守。