...
首页> 外文期刊>International Journal of Pharmaceutics >Suppression of agglomeration in fluidized bed coating. II. Measurement of mist size in a fluidized bed chamber and effect of sodium chloride addition on mist size.
【24h】

Suppression of agglomeration in fluidized bed coating. II. Measurement of mist size in a fluidized bed chamber and effect of sodium chloride addition on mist size.

机译:抑制流化床涂料中的团聚。二。在流化床室中测量雾度,以及添加氯化钠对雾度的影响。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

It has been reported that the degree of particle agglomeration in fluidized bed coating is greatly affected by the spray mist size of coating solution. However, the mist size has generally been measured in open air, and few reports have described the measurement of the mist size in a chamber of the fluidized bed, in which actual coating is carried out. Therefore, using hydroxypropylmethyl cellulose (HPMC) aqueous solution as a coating solution, the spray mist size of the coating solution in a chamber of the fluidized bed was measured under various coating conditions, such as the distance from the spray nozzle, fluidization air volume, inlet air temperature and addition of sodium chloride (NaCl) into the coating solution. The mist size in the fluidized bed was compared with that in open air at various distances from the spray nozzle. Further, the relationship between the spray mist size and the degree of suppression of agglomeration at various NaCl concentrations during fluidized bed coating was studied. The mist size distribution showed a logarithmic normal distribution in both cases of the fluidized bed and open air. The number-basis median diameter of spray mist (D50) in the fluidized bed was smaller compared with that in open air. D50 increased with the increasing distance from the spray nozzle in both cases. In the fluidized bed, D50 decreased with the increasing fluidization air volume and inlet air temperature. The effect of NaCl concentration on the mist size was hardly observed, but the degree of suppression of agglomeration during coating increased with the increasing NaCl concentration in the coating solution.
机译:据报道,流化床涂料中颗粒的团聚程度受涂料溶液的雾滴大小影响很大。然而,通常在露天中测量雾的尺寸,很少有报道描述在流化床的腔室中进行实际涂覆的雾尺寸的测量。因此,使用羟丙基甲基纤维素(HPMC)水溶液作为包衣溶液,在各种包衣条件下,如距喷嘴的距离,流化空气量,进气温度和向涂层溶液中添加氯化钠(NaCl)。将流化床中的雾大小与距喷嘴不同距离的露天中的雾大小进行了比较。此外,研究了在流化床涂覆过程中,在各种NaCl浓度下,喷雾尺寸与雾化程度之间的关系。在流化床和露天的情况下,雾的大小分布都显示出对数正态分布。与露天相比,流化床中的喷雾(D50)的基于数量的中值直径较小。在两种情况下,D50都随着距喷嘴距离的增加而增加。在流化床中,D50随着流化空气量和进气温度的升高而降低。几乎没有观察到NaCl浓度对雾度的影响,但是随着涂布溶液中NaCl浓度的增加,涂布期间的团聚抑制程度增加。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号